My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CLAREMONT
>
4905
>
2200 - Hazardous Waste Program
>
PR0516229
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/19/2020 5:20:43 PM
Creation date
5/19/2020 4:49:40 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0516229
PE
2227
FACILITY_ID
FA0012386
FACILITY_NAME
BRANNON TIRE - CLAREMONT
STREET_NUMBER
4905
STREET_NAME
CLAREMONT
City
STOCKTON
Zip
95207
APN
10223010
CURRENT_STATUS
01
SITE_LOCATION
4905 CLAREMONT
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
81
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN J OAQU I N Environmental Health Department <br /> CC LJ N T Y------- <br /> Large Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> BRANNON TIRE-CLAREMONT 4905 CLAREMONT , STOCKTON January 27, 2020 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> (f)Ancillary equipment shall be provided with full secondary containment(e.g., trench,jacketing, double-walled <br /> piping)that meets the requirements of subsections(b)and (c)of this section except for: <br /> (1)aboveground piping (exclusive of flanges,joints, valves, and connections)that are visually inspected for leaks on <br /> a daily basis; <br /> (2)welded flanges,welded joints, and welded connections that are visually inspected for leaks on a daily basis; <br /> (3)sealless or magnetic coupling pumps and sealless valves,that are visually inspected for leaks on a daily basis; <br /> and <br /> (4)pressurized aboveground piping systems with automatic shut-off devices(e.g., excess flow check valves,flow <br /> metering shutdown devices, loss of pressure actuated shut-off devices)that are visually inspected for leaks on a <br /> daily basis. <br /> CORRECTIVE ACTION: Have a qualified Professional Engineer update the tank assessment and add the missing <br /> sections. Provide a corrective action statement and supporting documentation to the San Joaquin County <br /> Environmental Health Department(EHD)within 30 days. Provide a copy of the updated assessment,when <br /> available. <br /> This is a repeat violation, Class II. <br /> 507 CCR 66265.195 Failed to conduct daily inspections of hazardous waste tank system and maintain records onsite. <br /> OBSERVATION: The facility has a hazardous waste tank but does not have three years of complete daily tank <br /> inspection records. The daily tank inspections were not available for review the following months: <br /> -June 2017 to May 2018 <br /> -April 2019 to January 2020 <br /> REGULATION GUIDANCE: (a)The owner or operator shall inspect,where present, at least once each operating <br /> day: <br /> (1)overfill/spill control equipment(e.g.,waste-feed cutoff systems, bypass systems, and drainage systems)to <br /> ensure that it is in good working order; <br /> (2)the aboveground portions of the tank system, if any, to detect corrosion or releases of waste; <br /> (3)data gathered from monitoring equipment and leak-detection equipment, (e.g., pressure and temperature <br /> gauges, monitoring wells)to ensure that the tank system is being operated according to its design; <br /> (4)the construction materials and the area immediately surrounding the externally accessible portion of the tank <br /> system including secondary containment structures(e.g., dikes)to detect erosion or signs of releases of hazardous <br /> waste (e.g.,wet spots, dead vegetation); and <br /> (5)for uncovered tanks,the level of waste in the tank, to ensure compliance with section 66265.194(b)(3). <br /> (c)The owner or operator shall document in the operating record of the facility an inspection of those items in <br /> subsection (a)of this section. <br /> CORRECTIVE ACTION: Immediately start conducting and documenting complete daily hazardous waste tank <br /> inspections. Provide a corrective action statement and supporting documentation to the San Joaquin County <br /> Environmental Health Department(EHD)within 30 days. <br /> This is a repeat violation, Class II. <br /> FA0012386 PR0516229 SCO01 01/27/2020 <br /> EHD 22-02 Rev.9/20/2019 Page 11 of 14 Large Quantity Hazardous Waste Generator OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.