COMPLIANCE INFO_2020
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CLAREMONT
>
4905
>
2200 - Hazardous Waste Program
>
PR0516229
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/19/2020 5:20:43 PM
Creation date
5/19/2020 4:49:40 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0516229
PE
2227
FACILITY_ID
FA0012386
FACILITY_NAME
BRANNON TIRE - CLAREMONT
STREET_NUMBER
4905
STREET_NAME
CLAREMONT
City
STOCKTON
Zip
95207
APN
10223010
CURRENT_STATUS
01
SITE_LOCATION
4905 CLAREMONT
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
81
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN J OAQU I N Environmental Health Department <br /> CC LJ N T Y------- <br /> Large Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> BRANNON TIRE-CLAREMONT 4905 CLAREMONT , STOCKTON January 27, 2020 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 601 CCR 66262.34(a)Stored hazardous waste on site longer than 90 days without a permit or authorization. <br /> OBSERVATION: The following hazardous waste containers were found on-site with an accumulation start date of <br /> greater than 90 days or no accumulation start date: <br /> -One approximately 30 gallon blue plastic drum of brake dust was observed in the hazardous waste storage area <br /> without an accumulation start date. The last disposal record for brake dust was dated 5/3/2019. <br /> REGULATION GUIDANCE: (a)a generator may accumulate hazardous waste on-site for 90 days or less <br /> (b)The beginning of the 90 day period is determined as follows: <br /> (1)if the generator does not generate more than 100 kilograms of hazardous waste or one kilogram of acutely <br /> hazardous waste(listed in section 66261.33(e))or one kilogram of extremely hazardous waste during any calendar <br /> month,the 90 day period begins on the date the generator has accumulated 100 kilograms of hazardous waste or <br /> one kilogram of acutely hazardous waste or one kilogram of extremely hazardous waste; <br /> (2)if the generator generates more than 100 kilograms of hazardous waste or one kilogram of acutely hazardous <br /> waste or one kilogram of extremely hazardous waste during any calendar month,the 90-day period begins on the <br /> first date on which any amount of hazardous waste begins to accumulate during that month. <br /> CORRECTIVE ACTION: Immediately dispose of the hazardous waste stored on site greater than 90 days in <br /> compliance with Title 22 California Code of Regulations. Provide a corrective action statement and a copy of the <br /> disposal records to the San Joaquin County Environmental Health Department(EHD)within 30 days. <br /> This is a repeat violation, Class ll. <br /> 605 CCR 66262.34(f) Failed to completely label containers or portable tanks of hazardous waste. <br /> OBSERVATION: Hazardous waste containers were observed on-site with incomplete labeling. The containers <br /> were: <br /> -One white plastic satellite container of brake dust was observed in the hazardous waste storage room with an <br /> incorrect accumulation start date of 9/28/2015 and missing hazardous properties. <br /> -One blue plastic approximately 30 gallon drum of brake dust was observed in the hazardous waste storage room <br /> without an accumulation start date. <br /> -One black metal 55 gallon drum of oily solids was observed in the hazardous waste storage area without the words <br /> "Hazardous Waste",generator name&address, physical state, accumulation start date and hazardous properties. <br /> -One black metal 55 gallon drum of used paper filters was observed in the hazardous waste storage area without an <br /> accumulation start date. <br /> -One red metal 55 gallon drum of used oil was observed under the filter crusher without a hazardous waste label. <br /> REGULATION GUIDANCE: All hazardous waste containers shall be marked with the following information: the <br /> words"Hazardous Waste", name and address of generator, hazardous properties, physical state, composition <br /> (contents), accumulation start date <br /> CORRECTIVE ACTION: Immediately label the containers as required for hazardous waste. Provide a corrective <br /> action statement and supporting documentation to the San Joaquin County Environmental Health Department <br /> (EHD)within 30 days. <br /> This is a repeat violation, Class ll. <br /> FA0012386 PR0516229 SCO01 01/27/2020 <br /> EHD 22-02 Rev.9/20/2019 Page 12 of 14 Large Quantity Hazardous Waste Generator OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.