Laserfiche WebLink
image 2, 9282 Shaw Road `�+ <br /> 4. If the three borings located outside of the former UST pit area are converted to <br /> groundwater monitoring wells, or obvious deep contamination is encountered in <br /> the boring located in the former tank pit area near boring B1, that boring should <br /> also be converted to a monitoring well. <br /> 5. The onsite domestic supply well should be sampled for laboratory analysis, and <br /> its location included on the site map. <br /> Please proceed with submittal of a San Joaquin County Well Permit Application, required <br /> $89.00 permit fee and $294 permit inspection fee and with scheduling the approved work. <br /> If you.have any questions please tali Lori Duncan at (209) 468-0337. <br /> Donna Heran, REHS, Director <br /> Environmental Health Department <br /> Lori Duncan, Senior REHS Nuel C. Henderson, Jr. PG <br /> LOP/Site Mitigation Unit IV Engineering Geologist, Unit IV } <br /> cc: James Barton, PG, CVRWQCB <br /> Steve Muir, Consultant <br /> r <br /> I <br /> 5 <br />