My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SITE INFORMATION AND CORRESPONDENCE
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
S
>
SHAW
>
1500
>
3500 - Local Oversight Program
>
PR0545688
>
SITE INFORMATION AND CORRESPONDENCE
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/21/2020 11:47:17 AM
Creation date
5/21/2020 9:42:10 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
SITE INFORMATION AND CORRESPONDENCE
RECORD_ID
PR0545688
PE
3528
FACILITY_ID
FA0003634
FACILITY_NAME
CANTEEN CORPORATION
STREET_NUMBER
1500
Direction
N
STREET_NAME
SHAW
STREET_TYPE
RD
City
STOCKTON
Zip
95205
APN
14326008
CURRENT_STATUS
02
SITE_LOCATION
1500 N SHAW RD
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
LSauers
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
596
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
%we N40W <br /> Site Update Repan-3rd Quarter 2009 October 72,2009 <br /> Former Canteen Facility <br /> Pa e 2 <br /> Dec 2005: Began installation of an upgraded configuration, which included an AS-SVE <br /> skid system, with vapor treatment via thermal/catalytic oxidizer. This configuration <br /> was selected to increase the capacity of the SVE flow rates, and in turn, allow full <br /> operation of all existing SVE wells. With all five SVE wells in operation, AS operations <br /> were increased to facilitate the completion of the site remediation objectives. <br /> an 2006: Operations of the upgraded system were initiated. All five vapor extraction <br /> (VE) wells were put into operation with the newer, larger-capacity equipment. <br /> Sep 2006: The AS-SVE System was shut down pending another Modification <br /> Application to the SJVAPCD. The modification proposed removing the oxidizer unit and <br /> replacing it with granular-activated carbon (GAC) vessels. Each vessel holds a total of <br /> 400 lbs of GAC and will be changed-out as necessary. <br /> Nov 2006: Operations of the AS-SVE System with GAC vessel treatment was initiated <br /> on November 8, 2006. Each GAC vessel holds a total of 400 lbs of GAC and will be <br /> changed-out as necessary. <br /> Jan-Mar 2007: AS-SVE operations, with vapor abatement via the GAC vessels, <br /> continued. The system uptime for this quarter was 92.6%. <br /> Aur-Jun 2007: AS-SVE operations, with vapor abatement via the GAC vessels, <br /> continued. The system uptime for this quarter was 93.8%, with minor down-time <br /> awaiting carbon change-outs. <br /> Jul-Sep„ 2007: AS-SVE operations, with vapor abatement via the GAC vessels, <br /> continued. The system uptime for this quarter was 91.4%, with minor down-time <br /> awaiting carbon change-outs. <br /> Oct-07/Feb-08: AS-SVE operations continued with vapor abatement via GAC <br /> vessels. The system uptime for this quarter was 100%. Untreated emissions began <br /> approaching a point where vapor treatment may not be necessary, per San Joaquin <br /> Valley Authority to Construct permit. <br /> Jan-Mar 2008: SJVAPCD gave permission to operate without vapor treatment on the <br /> system. The system uptime for this quarter was 99.3%. The carbon vessels have <br /> been kept on hand in case emissions begin to rise again. <br /> Apr-Jun 2008: SVE System operations have proceeded without vapor treatment. <br /> The system uptime for this quarter was 99.9%. <br /> Jul-Sep 2008: SVE System operations have proceeded without vapor treatment. <br /> Adjustments on UST vapor extraction wells to address residual concentrations revealed <br /> by the Delineation Assessment activities. The system uptime for this quarter was <br /> 93.6% due to down-time for rebuilding the AS Compressor. <br /> Oct-Dec 2008: SVE System operations have proceeded without vapor treatment. <br /> The system uptime for this quarter was 98.0%, with one high-level shutoff at the SVE <br /> separator. <br /> Jan-Mar 2009: SVE System operations have proceeded without vapor treatment. <br /> The system uptime for this quarter was 100%, with no shutdowns. <br /> Apr-Jun 2009: SVE System operations have proceeded without vapor treatment. <br /> The system uptime for this quarter was 99.9°/x, with only minor down-time due to <br /> high-temperature alarm on the AS and SVE Systems. <br />
The URL can be used to link to this page
Your browser does not support the video tag.