My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
6425
>
2300 - Underground Storage Tank Program
>
PR0231211
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/5/2021 1:26:49 PM
Creation date
5/21/2020 12:39:34 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0231211
PE
2371
FACILITY_ID
FA0002409
FACILITY_NAME
SAFEWAY FUEL CENTER #2707
STREET_NUMBER
6425
Direction
N
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
CURRENT_STATUS
01
SITE_LOCATION
6425 N PACIFIC AVE
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
196
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDERGROUND STORAGE TANK <br /> SECONDARY CONTAINMENT TESTING REPORT FORM (Pagel of 6) <br /> Type of Action ❑Installation Test ❑Repair Test Eil Six Month Test ❑x 36 Month Test <br /> I. FACILITY INFORMATION <br /> CERS ID Date of Secondary Containment Test <br /> 10156811 9/18/2019 <br /> Business Name(Same as Facility Name or DBA-Doing Business As) <br /> Safeway 2707 <br /> Business Site Address City ZIP Code <br /> 6425 N Pacific Ave Stockton 195207 <br /> II. UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of UST Service Technician Performing the Test(Print as shown on the ICC Certification) Phone# <br /> Mauricio Miranda (925) 671-9200 <br /> Contractor/Tank Tester License# ICC Certification# ICC Certification Expiration Date <br /> 256896 8407460 12/27/2021 <br /> III. SUMMARY OF SECONDARY CONTAINMENT TESTING RESULTS <br /> TANK ID: (By tank number,stored product, etc.) A T1-87 B T2-91 C T3-Diesel D <br /> Tank Containment <br /> Tightness Test Result O Pass ❑ Fail ❑ NA O Pass ❑ Fail ❑ NA El Pass ❑ Fail ❑NA ❑Pass ❑Fail ❑NA <br /> Product Piping Containment <br /> Tightness Test Result E Pass ❑ Fail ❑NA O Pass ❑Fail ❑NA E Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA <br /> Communication Test Result E Pass ❑Fail ❑NA E Pass ❑Fail ❑NA El Pass ❑Fail ❑NA ❑Pass ❑Fail ❑ NA <br /> Remote Fill Piping Containment <br /> Tightness Test Result ❑ Pass ❑Fail E NA ❑Pass ❑Fail O NA ❑Pass ❑Fail O NA ❑Pass ❑Fail ❑NA <br /> Communication Test Result ❑ Pass ❑ Fail O NA ❑ Pass ❑Fail O NA ❑Pass ❑Fail p NA ❑Pass ❑Fail ❑NA <br /> Vent Piping Containment <br /> Tightness Test Result O Pass ❑Fail ❑NA E Pass ❑Fail ❑NA E Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA <br /> Communication Test Result O Pass ❑Fail ❑ NA E Pass ❑ Fail ❑NA O Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA <br /> Vapor Recovery Piping Containment <br /> Tightness Test Result E Pass ❑Fail ❑ NA p Pass ❑Fail ❑NA E Pass ❑Fail ❑ NA ❑Pass ❑Fail ❑NA <br /> Communication Test Result O Pass ❑Fail ❑ NA O Pass ❑Fail ❑NA p Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA <br /> Turbine/Product Piping Sump <br /> Tightness Test Result p Pass ❑ Fail ❑NA E Pass ❑ Fail ❑ NA El Pass ❑Fail ❑NA ❑ Pass ❑Fail ❑NA <br /> Fill Riser Sump <br /> Tightness Test Result E Pass ❑Fail ❑NA E Pass ❑Fail ❑NA E Pass ❑Fail ❑NA ❑ Pass ❑Fail ❑NA <br /> VENT/TRANSITION SUMP ID: a Vent Box b C d <br /> Tightness Test Result E Pass ❑Fail ❑ NA ❑Pass ❑Fail ❑NA ❑Pass ❑Fail ❑ NA ❑Pass ❑ Fail ❑NA <br /> UDC ID: 1 Disp 1-2 2 Disp 3-4 3 Disp 5-6 4 Disp 7-8 <br /> Tightness Test Result E Pass ❑ Fail ❑NA E Pass ❑Fail ❑NA E Pass ❑Fail ❑ NA O Pass ❑Fail ❑NA <br /> UDC ID: 5 Disp 9-10 6 Disp 11-12 7 Disp 13-14 8 Disp 15-16 <br /> Tightness Test Result E Pass ❑Fail ❑NA E Pass ❑ Fail ❑ NA O Pass ❑Fail ❑NA E Pass ❑Fail ❑NA <br /> UDC ID: 9 10 11 12 <br /> Tightness Test Result ❑ Pass ❑Fail ❑ NA ❑Pass ❑ Fail ❑NA ❑Pass ❑ Fail ❑NA ❑ Pass ❑ Fail ❑NA <br /> All items marked"Fail'or"NA"must be explained in their respective"COMMENTS"section. <br /> IV. CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THISZESTING <br /> I hereby certify that the secondary containment was tested in accordance with California Code of RegulationsT�tl vision <br /> 3,Chapter 16,Section 2637 and all the information contained herein is accurate. i U 1 <br /> UST Service Technician Signature / <br /> a"-b a �-IP& ENVIRON1 , I <br /> CERS=California Environmental Reporting System,ID=Identification,UST=Underground Storage Tank,ICC=International Code Council,NA=Not Applicable.UDC=Under- <br /> Dispenser Containment <br />
The URL can be used to link to this page
Your browser does not support the video tag.