Laserfiche WebLink
Addendum to the Well Installation and <br /> Hydraulic Testing Report and Additional <br /> ARCADIS Well Installation Work Plan <br /> Former Occidental Chemical Corporation <br /> Lathrop, California <br /> Location Zone Date Sampled Sulfolane /L) DBCP /L EDB(N /L) <br /> LP010 Water table 1/19/2012 ND <20 ND <0.01 ND <0.02 <br /> 3/29/2012 28 -- -- <br /> 7/19/2012 22 -- -- <br /> LP011 Water table 1/19/2012 ND <20 ND <0.01 ND <0.02 <br /> 7/19/2012 ND <20 -- -- <br /> PW01-48 Water table 9/09/2005 ND <20 -- -- <br /> 1/19/2012 ND <20 ND <0.01 ND <0.02 <br /> 7/19/2012 ND <20 -- -- <br /> PW01-129 Intermediate 9/01/2005 75 -- -- <br /> PW02-40 Water table 9/07/2005 ND <20 -- -- <br /> PW02-80 Shallow 9/07/2005 ND <20 -- -- <br /> PW03-49 Water table 9/06/2005 ND <20 -- -- <br /> PW03-142 Intermediate 9/06/2005 ND <20 -- -- <br /> Notes: <br /> ND=not detected above the laboratory reporting limit. The reporting limit is presented in parentheses. <br /> Supply wells and LP wells are Simplot wells; PW wells are GSH wells. <br /> These results were taken into account when contouring COC isoconcentration maps(Figures 7 <br /> through 10) and are consistent with the current conceptual site model. Furthermore,these results <br /> provide new information regarding the nature and extent of the COC plume east of South Howland <br /> Road.Additional sampling may be needed to delineate the extent of sulfolane in this area to inform <br /> extraction well placement. Following additional investigation and monitoring, additional extraction wells <br /> can be installed or extraction rates adjusted to remove sulfolane-affected groundwater.These data also <br /> highlight the benefits of using an adaptive, phased approach to the placement and operation of <br /> extraction and injection wells. <br /> BSW Operation <br /> Currently the Simplot BSW is not being used. Based on information provided by Simplot,this well <br /> serves as a temporary replacement for the PSW, providing for process water, potable water, <br /> emergency safety showers, and emergency fire suppression if needed. During the summer months, <br /> Simplot historically allowed a neighboring farmer to use water from the Simplot BSW to irrigate alfalfa. It <br /> is GSH's understanding that Simplot intends to maintain this arrangement in the future. <br /> In light of the recent sulfolane detection in the Simplot BSW,ARCADIS is constructing a temporary <br /> treatment system to remove sulfolane from groundwater that is pumped from the BSW.The design and <br /> operation of the temporary treatment system will be described in a memorandum to be submitted to the <br /> RWQCB in September 2012.The temporary Simplot BSW treatment system will be used on an <br /> emergency basis to supply process water if the PSW needs to be shut off temporarily.A permanent <br /> Simplot BSW treatment system will be constructed to treat an minimum of 250 gpm and up to 700 gpm <br /> 2012-09-13 addendum well install work plan_hy test rpt.doex 9 <br />