My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0007185
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
TURNPIKE
>
1601
>
2900 - Site Mitigation Program
>
PR0521845
>
ARCHIVED REPORTS_XR0007185
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/28/2020 4:13:26 PM
Creation date
5/28/2020 4:09:06 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0007185
RECORD_ID
PR0521845
PE
2950
FACILITY_ID
FA0014838
FACILITY_NAME
LOPEZ PROPERTY
STREET_NUMBER
1601
STREET_NAME
TURNPIKE
STREET_TYPE
RD
City
STOCKTON
Zip
95206
APN
16504013
CURRENT_STATUS
01
SITE_LOCATION
1601 TURNPIKE RD
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
LSauers
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 <br />' Quarterly Report - Second Quarter 2006 <br /> LOPEZ PROPERTY <br />' 1601 Turnpike Road, Stockton, California <br />' 1.0. INTRODUCTION <br /> At the request of Ms Mabel Keir, Advanced GeoEnvironmental, Inc (AGE) has prepared this <br /> quarterly report for the property located at 1601 Turnpike Road, Stockton, California (site) The <br /> scope of work included conducting a quarterly ground water monitoring event and the preparation <br /> of this report The site setting is illustrated on Figure 1 Site structures and monitoring well locations <br /> are depicted on Figure 2 <br /> This report has been prepared in accordance with guidelines issued by the Central Valley Regional <br /> rWater Quality Control Board (CVRWQCB) for investigation of underground storage tank (UST) <br /> sites A historical site background is summarized in Appendix A <br /> 1 <br /> 2.0. PROCEDURES <br />' Three monitoring wells (MW-1 through MW-3) were monitored and sampled on 19 April 2006' <br /> Field work was performed in accordance with San Joaquin County Environmental Health <br /> Department (EHD) guidelines for sampling ground water monitoring wells and CVRWQCB <br /> guidelines for the investigation of UST sites <br />' 21 QUARTERLY WELL MONITORING PROCEDURES <br />' On 19 April 2006,the depths to ground water in the three monitoring wells were measured from the <br /> top of each well casing to the nearest 0 01-foot utilizing a Solinst water level meter, ground water <br /> elevations for each well were calculated by subtracting the measured depth to ground water from the <br />' surveyed casing elevation (Table 1) After water levels were measured, approximately 6 to 8 5 <br /> gallons of water (a minimum of 3 casing-water volumes per well) were purged from monitoring <br />' wells MW-1 through MW-3 using dedicated disposable plastic bailers Ground water temperature, <br /> pH and conductivity were measured at regular intervals during purging using an Oakton water <br /> analyzer Field sheets and data are included in Appendix B Purged water was stored in properly <br />' Iabeled Department of Transportation (DOT)-approved 55-gallon drums on-site <br />' 22 COLLECTION AND ANALYSIS OF GROUND WATER SAMPLES <br /> Water samples were collected from each monitoring well using the dedicated, disposable plastic <br />' bailers after allowing the well to achieve a minimum 80%recovery of the pre-purge water volume <br /> The samples from each well were transferred into three 40-milliliter (ml) volatile organic analysis <br /> . (VOA)vials The samples were labeled with the monitoring well designation,date,time of sampling, <br />' Advanced GcoEnvironmentel,Inc <br /> r <br /> 1 <br />