Laserfiche WebLink
S0 JOA U 1 Environmental Health Department <br /> U ; i y <br /> 91 Small Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> West Wind 100 S VENTURA AVE, STOCKTON June 02, 2020 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 301 CCR 66262.34(d)(2) Facility not maintained to minimize the release of a hazardous waste. <br /> OBSERVATION: <br /> One 55-gallon drum of used oil was observed with used oil pooling on top of the drum. <br /> One used oil stain was observed outside the southwest corner of the terminal building. The stain was <br /> approximately 10 feet by 2 feet and appeared to be on asphalt. <br /> REGULATION GUIDANCE:A hazardous waste generator must maintain and operate its facility to minimize the <br /> possibility of a fire, explosion, or any unplanned sudden or non-sudden release of hazardous waste or hazardous <br /> waste constituents to air, soil, or surface water which could threaten human health or the environment. <br /> CORRECTIVE ACTION: <br /> Immediately place all used oil in closed containers. <br /> Immediately cleanup the oil stain and dispose of the absorbent waste in accordance with hazardous waste control <br /> law. <br /> Manage the waste according to Title 22 California Code of Regulations for hazardous waste. Submit a statement <br /> and supporting documentation to the San Joaquin County Environmental Health Department describing the storage <br /> and final disposition of the cleaned up waste. <br /> This is a Class II violation. <br /> 302 CCR 66262.34(d)(2) Failed to maintain required emergency equipment. <br /> OBSERVATION: The facility is not equipped with the absorbent materials to cleanup used oil spills. <br /> REGULATION GUIDANCE: <br /> All facilities shall be equipped with the following, unless it can be demonstrated to the Department that none of the <br /> hazards posed by waste handled at the facility could require a particular kind of equipment specified below: <br /> (a)an internal communications or alarm system capable of providing immediate emergency instruction (voice or <br /> signal)to facility personnel; <br /> (b)a device, such as a telephone(immediately available at the scene of operations)or a hand-held two-way radio, <br /> capable of summoning emergency assistance from local police departments,fire departments, or State or local <br /> emergency response teams; <br /> (c)portable fire extinguishers,fire control equipment(including special extinguishing equipment, such as that using <br /> foam, inert gas, or dry chemicals), spill control equipment, and decontamination equipment; and <br /> (d)water at adequate volume and pressure to supply water hose streams, or foam producing equipment, or <br /> automatic sprinklers, or water spray systems . <br /> CORRECTIVE ACTION: Immediately obtain and retain on site spill control materials . Provide a corrective action <br /> statement and supporting documentation to the San Joaquin County Environmental Health Department within 30 <br /> days. <br /> This is a Class II violation. <br /> FA0011052 PRO539720 SCO01 06/02/2020 <br /> EHD 22-01 Rev.9/20/2019 Page 8 of 11 Small Quantity Hazardous Waste Generator OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />