My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
N
>
NAGLEE
>
2477
>
2200 - Hazardous Waste Program
>
PR0540511
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/3/2020 10:05:10 AM
Creation date
6/2/2020 3:42:37 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0540511
PE
2220
FACILITY_ID
FA0018246
FACILITY_NAME
PetSmart #1164
STREET_NUMBER
2477
STREET_NAME
NAGLEE
STREET_TYPE
Rd
City
Tracy
Zip
95304
CURRENT_STATUS
01
SITE_LOCATION
2477 Naglee Rd
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
498
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Chemwatch:4650.13 Page 9 of 18 Issue Date:11/12/2018 <br /> Version No:7.1.1.1 API Pond Ammonia Test Solution#1 Print Date:06/21/2019 <br /> For general applications,gloves with a thickness typically greater than 0.35 mm,are recommended. <br /> It should be emphasised that glove thickness is not necessarily a good predictor of glove resistance to a specific <br /> chemical,as the permeation efficiency of the glove will be dependent on the exact composition of the glove material. <br /> Therefore,glove selection should also be based on consideration of the task requirements and knowledge of breakthrough <br /> times. <br /> Glove thickness may also vary depending on the glove manufacturer,the glove type and the glove model.Therefore,the <br /> manufacturers'technical data should always be taken into account to ensure selection of the most appropriate glove for <br /> the task. <br /> Note:Depending on the activity being conducted,gloves of varying thickness may be required for specific tasks.For <br /> example: <br /> Thinner gloves(down to 0.1 mm or less)may be required where a high degree of manual dexterity is <br /> needed.However,these gloves are only likely to give short duration protection and would normally be just for <br /> single use applications,then disposed of. <br /> Thicker gloves(up to 3 mm or more)may be required where there is a mechanical(as well as a chemical) <br /> risk i.e.where there is abrasion or puncture potential <br /> Gloves must only be worn on clean hands.After using gloves,hands should be washed and dried thoroughly.Application <br /> of a non-perfumed moisturiser is recommended. <br /> Body protection See Other protection below <br /> Overalls. <br /> PVC Apron. <br /> Other protection PVC protective suit may be required if exposure severe. <br /> Eyewash unit. <br /> Ensure there is ready access to a safety shower. <br /> Respiratory protection <br /> Type A-P Filter of sufficient capacity.(AS/NZS 1716&1715,EN 143:2000&149:2001,ANSI Z88 or national equivalent) <br /> Cartridge respirators should never be used for emergency ingress or in areas of unknown vapour concentrations or oxygen content. <br /> r The wearer must be warned to leave the contaminated area immediately on detecting any odours through the respirator.The odour may indicate that the mask is not functioning properly,that the <br /> vapour concentration is too high,or that the mask is not properly fitted.Because of these limitations,only restricted use of cartridge respirators is considered appropriate. <br /> r Cartridge performance is affected by humidity.Cartridges should be changed after 2 hr of continuous use unless it is determined that the humidity is less than 75%,in which case,cartridges <br /> can be used for 4 hr.Used cartridges should be discarded daily,regardless of the length of time used <br /> SECTION 9 PHYSICAL AND CHEMICAL PROPERTIES <br /> Information on basic physical and chemical properties <br /> Appearance Reddish-orange liquid with a mild odour;mixes with water. <br /> Physical state Liquid Relative density(Waterl� 1.152 <br /> Odour Not Available Partition coefficient Not Available <br /> n-octanol/water <br /> Odour threshold Not Available Auto-ignition temperatur)e Not Applicable <br /> pH(as supplied) 8.3 Decomposition Not Available <br /> temperature <br /> Melting point/freezing Not Available Viscosity(cSt) Not Available <br /> point(°C) <br /> Initial boiling point and Not Available Molecular weight(g/mol) Not Applicable <br /> boiling range(°C) <br /> Flash point(°C) Not Applicable Taste Not Available <br /> Evaporation rateNot Available Explosive properties Not Available <br /> Flammability Not Applicable Oxidising properties Not Available <br /> Upper Explosive Limit Surface Tension(dyn/cm <br /> Not Applicable Not Available <br /> N or mN/m) <br /> Lower Explosive Limit Volatile Component <br /> N (%vol)Not Applicable Not Available <br /> Vapour pressure(kPa) Not Available Gas group Not Available <br /> Solubility in water Miscible pH as a solution(1%) Not Available <br /> Vapour density(Air=1) Not Available VOC g/L Not Available <br /> SECTION 10 STABILITY AND REACTIVITY <br /> Continued... <br />
The URL can be used to link to this page
Your browser does not support the video tag.