Laserfiche WebLink
proof container. A hazardous material label is placed on the container and a work order is <br /> generated or the store calls the Pep Boys Waste Hotline at 800.334.3794 to schedule a pick up. <br /> The Quick-Sorb Oil-Dri white container and used absorbent observed at the store has been <br /> transferred to the spill kit, a hazardous waste label has been sent to the store for placement on <br /> the spill kit and a work order was generated to pick it up and disposed by a certified waste <br /> hauler. Absorbent was noted as observed all over the front parking lot. Discussions with store <br /> management confirm this is not absorbent but seeds from the existing palm trees located on <br /> the property and surrounding properties. <br /> No. 132- Failed to maintain a log for daily tank inspections (used oil). (CCR 66265.195(c)) <br /> Store #711 maintains a Hazardous Waste Tank System Daily Inspection Log. Additional copies <br /> were sent to the store on August 5, 2013. Oscar Martinez, Service Manager, confirmed the <br /> used oil tank daily inspection log is now current. <br /> No. 133- Failed to comply with new HW tank system assessment requirements. (CCR <br /> 66265.192) <br /> A Hazardous Waste Tank System Assessment for Store #711 was performed by a California <br /> professional engineer in February 2012. A copy was sent to the store. Attachment A is a copy <br /> of this assessment. <br /> No. 135- Failed to submit a written response within 30 days of receiving an inspection report. <br /> (HSC25185(c)(3)) <br /> Pep Boys Store Support is unable to find documents pertaining to the November 4, 2010 <br /> hazardous waste inspection report. The report was included with this inspection. Written <br /> responses will address these violations in a separate referenced document. <br /> No. 301—Facility not maintained to minimize the release of a hazardous waste. (CCR <br /> 66265.31) <br /> Pep Boys Store #711 follows environmental policies and procedures to minimize and contain <br /> spills and/or releases. Spill kits are maintained at each facility. In any event, the Property <br /> Management Help Desk must be contacted immediately. The Help Desk will contact the <br /> Environmental Department, who will give additional instructions as to notification <br /> requirements (Fire, Police and Regulatory Agencies) and dispatch an Emergency Response <br /> contractor to perform corrective action. If the spill occurs after normal working hours for the <br /> Help Desk,the Environmental Department is contacted via cell phone or email. <br /> No. 305—Failed to maintain all communication or alarm systems,spill control, or <br /> decontamination equipment. (CCR 66265.33) <br /> Six (6) eyewash bottles were ordered on August 2, 2013 and the store received on August 8, <br /> 2013. The eyewash bottles new expiration date is March, 2016. <br /> 3111 West Allegheny Avenue/ Philadelphia,PA 19132 <br /> 215.430.9530(phone))215.430.4639(fax) <br />