My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WEST
>
4987
>
2200 - Hazardous Waste Program
>
PR0513935
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/9/2020 8:58:13 PM
Creation date
6/3/2020 9:21:17 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0513935
PE
2227
FACILITY_ID
FA0003969
FACILITY_NAME
PEP BOYS #711
STREET_NUMBER
4987
STREET_NAME
WEST
STREET_TYPE
LN
City
STOCKTON
Zip
95210
APN
10416027
CURRENT_STATUS
01
SITE_LOCATION
4987 WEST LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\HW\HW_2227_PR0513935_4987 WEST_.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
389
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Pep Boys#711 <br /> (k)(9)(D)any structural damage or inadequate construction or installation such as cracks, <br /> punctures,damaged fittings.All discrepancies shall be documented in the assessment and <br /> remedied before the tank system is placed in use.No discrepancies were noted.See Table IV.. <br /> (k)(10)all new tanks and ancillary equipment shall be tested for tightness prior to being placed <br /> in use.The results of the test(s)shall be documented in this assessment;Tank system integrity <br /> or leak test requirements must be in compliance with all local requirements.Prior to conducting <br /> a'tank system integrity test or leak test,contact local agency staff for local requirements.The <br /> tank was pressure tested under 3 psi pressure by the manufacturer(See Appendix B). in <br /> addition, the tank=is 18 years old and has not leaked This performance shows that the tank was <br /> tight as installed <br /> (k)(11)estimated<remaining service life of the tank system based on findings of subsections <br /> (k)(1)through(k)(10).The estimated remaining service life of the;tank is five years. <br /> (1)and(m)Not applicable—generator is not replacing parts of the system. <br /> Section 66265.133 Requirements <br /> (a)In order to prevent the release of hazardous waste or hazardous constituents to the <br /> environment,secondary containment that meets the requirements of this section shall be <br /> provided(except as provided in subsections(f)and(g)of this section):- <br /> (1)for all new tank systems or components,prior to the tank system or component <br /> being put into service,not applicable—tanksystem has been put into service. <br /> (2)for all existing tank systems,unless, <br /> (A)the owner or operator is as defined in 40 CFR section 261.5,or a 100 to 1000 kg per <br /> month generator as defined in 40 CFR section 265.201,or Not applicable—generator is <br /> nota conditionally°exempt small quantity generator. <br /> (B)the owner or operator is not subject to regulation in 40 CFR part 265 pursuant to an <br /> exemptionin 40 CFR section 265.1.Not applicable-owner is subject to regulation. <br /> (b)Secondary containment systems shall be- <br /> (1)designed,installed,and operated to prevent any migration of wastes or <br /> accumulated liquid out of the system to the soil,ground water,or surface water at any <br /> f..) <br />
The URL can be used to link to this page
Your browser does not support the video tag.