VERMCATION LABORATORY ANALYSIS <br /> BTX & E CL HC TOTAL MTBE METALS PCB <br /> TANK TANK TPH-G TPH-D LEAD TBA, ICRP/ 8270 <br /> # CONTENTS 8015 8015 8020 8010 7420 DIPE, AES or 8080 <br /> ;7 8260 8260 8260 8240 ETRE, AA <br /> 7421 TAME <br /> 8260 <br /> LEADED GAS X X <br /> UNL GAS X X <br /> DIESEL X X <br /> KEROSENE X X <br /> UNK FUEL X X X <br /> PROD. OIL X X <br /> CHLOR. X X <br /> SOLVENTS <br /> NONCHLOR X X <br /> SOLVENTS <br /> WASTE% X X X X <br /> USED OIL X X <br /> 1. Third Edition. Those methods not found in <br /> All analysis methods are the designated EPA methods described in EPA SW 846, <br /> SW 846 are specifically noted below. Refer to the "SWRCB LUFT Field Manual", Appendix D (B), Table 3-5 on page A20 for <br /> minimum detection limits for motor vehicle fuel(gasoline and diesel). Refer to 1-2-3 "Regional Board Staff Recommendations <br /> for Initial Evaluation and investigation of UST for the waste and motor oil minimum detection limits. <br /> Detection Limits that remain below the MCL, STLC or Allowable Limit of the contaminant in question will be accepted, <br /> however laboratory shall utilize the most conservative method. <br /> LABORATORY ANALYSES TERMINOLOGY: <br /> Total Petroleum Hydrocarbon,Gasoline. GC/FID(5030) 8015 mod or GCIMS 8260 <br /> TPH-G GC/FID(3550). 9015 mod or GCIMS 8260 <br /> TPH-D Total Petroleum Hydrocarbon.Diesel,G <br /> Benzene,Toluene,Xylene&Ethyl Benzene, GCIPID 8MO or GCIMS 8260 <br /> BTX&E Chlorinated Hydrocarbon,GCIHSD Solo,GC/MS 8240 <br /> CL HC <br /> TOTAL LEAD Total lead,AA 7420, AA 7421 or ICP-AES 6010 <br /> MTBE,TA1V1E,DjPE.TBA GC/MS 8260 6010 or Atomic Absorption Spectrometry 7000. <br /> METALS ICAP or AA Inductively Coupled Plasma Atomic Emission Spectrometry <br /> Metals:Cadmium,Chromium III and VI,Lead,Zinc and Nickel. <br /> PCB polychlorinated Biphenyls, GC/MS 8270 or 8080 <br /> GC-FID Gas Chromatography,Flame Ionization Detection <br /> Method 3050 Acid digestion <br /> Method 3540 Soxhlet sample preparation method <br /> Method 3550 Sonication sample preparation,extraction <br /> Method 5030 purge and trap sample preparation <br /> QA/QC Quality Assurance/Quality Control is are to be used. Fused capillary columns are preferred to pac.ked <br /> Notes: To avoid false positive detection of benzene,benzene-free sol ven the ns have been characterized and proper <br /> columns, a packed column may be used as a*first cut" with"dirty* samples or once hydrocarbo <br /> QA/QC is followed. that the 500 series for volatile organic should be used in preference to the 600 series because the <br /> For drinking water sources,EPA recommends ng any level of heavy metal containination may require further analysis. <br /> detection limits are lower and the QA/QC is better. Samples exhibiti _ <br /> PHS-EHD recommends holding those samples until disposal is indicated. <br /> EH 23 046 (Revised 10/19/98) Page 8 <br />