COMPLIANCE INFO_2001-2005
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
R
>
ROTH
>
850
>
2300 - Underground Storage Tank Program
>
PR0231898
>
COMPLIANCE INFO_2001-2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/10/2020 2:10:33 AM
Creation date
6/3/2020 9:43:08 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2001-2005
RECORD_ID
PR0231898
PE
2332
FACILITY_ID
FA0003966
FACILITY_NAME
SHARPE SITE/DEF LOG AGENCY
STREET_NUMBER
850
Direction
E
STREET_NAME
ROTH
STREET_TYPE
RD
City
LATHROP
Zip
95330
APN
19802001
CURRENT_STATUS
02
SITE_LOCATION
850 E ROTH RD
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2332_PR0231898_850 E ROTH_2001-2005.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
423
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CONTRACTORS QUALITY REPORT (QC.•R) <br />SUBMIT DAILY TO T REPRESENTATIVE <br />REPORT NUMBER MW <br />DAILY LOG OF CONST#TROL <br />TION - MILITARY <br />362 PAGE 1 <br />PROJECT <br />DATE <br />TO -0007 Remove 2 UST's, Install 1 AST <br />30 Apr 2001 <br />CONTRACT NUMBER <br />DDJC-Sharpe Site, CA <br />DACW05-00-D-0008 <br />CONTRACTOR (Or hired labor) <br />1. WEATHER <br />Geofon Inc. <br />No Interruption, No Precipitation <br />Temperature Min 65F Max 82F <br />SUPERVISOR <br />2. QC NARRATIVE(S) <br />Subject: General Comments: <br />Geofon crew arrived on site at 0830. Preparations were made for the AST move <br />that was to occur today. I went to Don Valentines office at 0900 and <br />downloaded all of the dailies and in/out information up to day. I also <br />informed Don of the lift time for the AST 1200 hrs. The AST pad was drained <br />and cleaned for marking for the AST. Kleinfelder called and verbally gave me <br />the results of the 7 day break test. The result was 3470 psi. We're ready to <br />set the AST. <br />The crane truck arrived at 1200 hrs. An inspection was conducted. Don(COE) was <br />present during the inspection. The 75 ton crane was supplied by TRS Inc. It <br />passed all visual inspection. <br />The low bed from Hertz arrived at the same time as the crane truck. <br />The crane truck set up on the back side of the AST and lifted it onto the low <br />bed. The crane and truck then transported the AST to the. building 330 site. <br />The AST was then unloaded at approximately 1345 hrs. <br />There are no incidents to report. <br />A base representative arrived and stated that the fuel would be transferred <br />within the next couple of days. <br />I informed Fred Martin (COR) of the schedule change. We will not be removing <br />the USTs until the last week of next month. <br />Some of the appertenances were placed on the AST. <br />The site was secured and Jose went to CPE to obtain some more necessary items <br />for the AST. <br />Subject: Safety Inspections/Meetings: <br />Safety around cranes was discussed today. workers will not be within 20 feet <br />of the lifting objects. Workers will not get close to the AST until it is <br />safe. All of the hazard analysis topics were discussed. I also allowed the <br />crane operator to give his imput on safety issues. All issues have been <br />discussed. <br />3. ACTIVITIES STARTED OR FINISHED <br />The following activities were finished today: <br />R00001-003 AST Installation <br />4. PREP/INITIAL INSPECTIONS <br />Initial Inspection was held today for AST RELOCATION. <br />7 <br />7 <br />�J <br />J <br />