My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2001-2005
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
R
>
ROTH
>
850
>
2300 - Underground Storage Tank Program
>
PR0231898
>
COMPLIANCE INFO_2001-2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/10/2020 2:10:33 AM
Creation date
6/3/2020 9:43:08 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2001-2005
RECORD_ID
PR0231898
PE
2332
FACILITY_ID
FA0003966
FACILITY_NAME
SHARPE SITE/DEF LOG AGENCY
STREET_NUMBER
850
Direction
E
STREET_NAME
ROTH
STREET_TYPE
RD
City
LATHROP
Zip
95330
APN
19802001
CURRENT_STATUS
02
SITE_LOCATION
850 E ROTH RD
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2332_PR0231898_850 E ROTH_2001-2005.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
423
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GEOFON <br />I N C O R P O R A T E O <br />65 QUINTA COURT, SUITE D, SACRAMENTO, CA 95823 <br />16 January 2002 TELEPHONE: (916) 681-3601 • FAX (916) 681-3628 <br />INTERNET: www.geofon.com <br />Mr. Larry Smith <br />Administrative Contracting Officer <br />Sacramento Resident Office <br />Corps of Engineers <br />2194 Ascot Avenue <br />Rio Linda, California 95673-9988 <br />Subject: Comments / Responses <br />Underground Storage Tanks Closure Report, Building 330 <br />Lathrop, California <br />Contract No. DACW05-00-D-0008, Delivery Order # 0007 <br />Geofon Project No. 05-5546 <br />Dear Mr. Smith: <br />The following are responses to the comments made by Maurice Benson (DDJC) and John <br />Guzman (DDJC) regarding the closure report for the UST removal activity at Building 330. <br />Comment - Page 12 - "On page 12 paragraph 2, it mentions that the range of test results (for <br />TPH-D) in samples SP -1, SP -2, SP -4, SP -5 and SP -6 was from 12 to 190 mg/kg. Table 3 <br />indicates that the results for those sample IDs ranged from 12 to 21 mg/kg. The result of 190 <br />mg/kg was a duplicate sample taken with the pipeline samples PL -1 and PL -2". <br />Response - The range of test results (for TPH-D) in samples SP -1, SP -2, SP -4, SP -5 and SP -6 <br />has been changed from 12 to 190 mg/kg to 12 to 21 mg/kg. <br />Comment - Tables 2 & 3: Is T DUP-1 a duplicate of T-6? Clarify" <br />Response - Yes, T DUP -I is a duplicate of T-6. Changes have been made to tables 2 & 3. <br />Comment - Tables 2&3: "Is DUP-1 a duplicate of PL -2. Clarify" <br />Response - Yes, DUP -1 is a duplicate of PL -2. Changes have been made to tables 2 & 3. <br />Comment - Table 1: "Add cross reference ID matrix." RI/FS UST # SJC-EHD UST# <br />62 TA 1898-52 <br />76 TA 1898-53 <br />Response - The cross reference ID matrix suggested has been made on Table]. <br />
The URL can be used to link to this page
Your browser does not support the video tag.