Laserfiche WebLink
dh <br />INDIVIDU ANK/LINE/LEAK DETECTOR T REPORT NDE <br />NDE ENVIRONMENTAL CORPO ATION ., <br />TEST DATE: March 22, 1994 WORK ORDER NUMBER: 962319 <br />CLIENT: SHELL OIL COMPANY SITE: SHELL 204-7524-3505 <br />TANKTEST RESULTS IF LEAK DETECTORRESULTS <br />Test method: <br />VPLT <br />TANK INFORMATION <br />1.82 <br />Tank ID: <br />NORTH #1 <br />Bottom to top fill in inches: <br />139.0 <br />Product: <br />REG UNLEAD <br />Bottom to grade fill in inches: <br />144.0 <br />Capacity in gallons: <br />5.225 <br />Fill pipe length in inches: <br />44.0 <br />Diameter in inches: <br />95.00 <br />Fill pipe diameter in inches: <br />4.0 <br />Length in inches: <br />173 <br />Stage I vapor recovery: <br />DUAL <br />Material: <br />Tank: <br />STEEL <br />YES <br />Stage II vapor recovery: <br />BALANCE <br />Manifolded Vent: <br />No <br />RESULT: <br />PASS <br />V/R: <br />NO <br />Pump type: PRESSURE Pump make: RED JACKET <br />COMMENTS <br />TANKTEST RESULTS IF LEAK DETECTORRESULTS <br />Test method: <br />VPLT <br />Psi at tank bottom: <br />1.82 <br />Fuel level in inches: <br />68.75 <br />UFT/OFT: <br />UFT <br />Fuel volume in gallons: <br />4,049 <br />Water level in inches: <br />0.00 <br />Test time: <br />21:13-00:15 <br />Number of thermisters: <br />5 <br />Specific gravity: <br />0.734 <br />Water table depth in inches: <br />49 <br />Determined by (method): <br />NO WELL <br />Leak rate in gph: <br />0.004 <br />RESULT. <br />PASS <br />New/passed Failed/replaced <br />detector detector <br />Test method: FTA <br />Make: RED JACKET <br />Model: X.L.D. <br />S/N: 501920814 <br />Open time in sec: 3.00 <br />Holding psi: 14 <br />Resiliency cc: 120 <br />Test leak rate ml/h: 189.0 <br />Metering psi: 10 <br />Calib. leak in gph: 3.00 <br />RESULT: PASS <br />Test method: UTS-4 SYSTEM <br />Test time: 01:08-01:38 <br />Ullage volume: 1,176 <br />Ullage pressure: 2.40 <br />RESULT. PASS <br />DATA FOR UTS-4T ONLY: <br />Time of test 1: 01:08-01:18 <br />Temperature: 63.30 <br />Flow rate: 0.200-0.200 <br />Time of test 2: 01:18-01:28 <br />Temperature: 63.30 <br />Flow rate: 0.200-0.200 <br />Time of test 3: 01:28-01:38 <br />Temperature: 63.30 <br />Flow rate: 0.200-0.100 <br />COMMENTS <br />AVENU <br />Material: FIBERGLASS <br />Diameter (in): <br />2.0 <br />Length (in): <br />100.0 <br />Test psi: <br />50 <br />Bleedback cc: <br />0 <br />Test start time <br />30 <br />Test 1: start time: <br />22:18 <br />finish psi: <br />66 <br />vol change cc: <br />12 <br />Test 2: start time: <br />22:28 <br />finish psi: <br />49 <br />vol change cc: <br />7 <br />Test 3: start time: <br />22:38 <br />finish psi: <br />49 <br />vol change cc: <br />5 <br />Final gph: <br />0.013 <br />RESULT: <br />PASS <br />Test type: PTK-88 <br />Pump type: PRESSURE Pump make: RED JACKET <br />CALIFORNIA <br />