Laserfiche WebLink
INDIVIDUAWNK/LINE/LEAK DETECTOR TMREPORT <br />NDE ENVIRONMENTAL CORPORATION <br />TEST DATE: March 22, 1994 WORK ORDER NUMBER: 962319 <br />CLIENT: SHELL OIL COMPANY SITE: SHELL 204-7524-3505 <br />TANK TEST RESULTS <br />TANK INFORMATION <br />Test method: <br />Tank ID: <br />SOUTH #2 <br />Bottom to top fill in inches: <br />139.0 <br />Product: <br />REG UNLEAD <br />Bottom to grade fill in inches: <br />143.0 <br />Capacity in gallons: <br />5.225 <br />Fill pipe length in inches: <br />44.0 <br />Diameter in inches: <br />95.00 <br />Fill pipe diameter in inches: <br />4.0 <br />Length in inches: <br />173 <br />Stage I vapor recovery: <br />DUAL <br />Material: <br />Tank: <br />STEEL <br />YES <br />Stage II vapor recovery: <br />BALANCE <br />Manifolded Vent: <br />No <br />Open time in sec: <br />Number of thermisters: <br />V/R: <br />No <br />Holding psi: <br />Specific gravity: <br />0.734 <br />COMMENTS <br />Water table depth in inches: <br />Test leak rate ml/h: <br />Determined by (method): <br />NO WELL <br />Metering psi: <br />Leak rate in gph: <br />TANK TEST RESULTS <br />LEAK DETECTOR: RESULTS <br />Test method: <br />VPLT <br />New/passed Failed/replaced <br />Psi at tank bottom: <br />1.80 <br />detector detector <br />Fuel level in inches: <br />68.25 <br />Test method: <br />UFT/OFT: <br />UFT <br />Make: <br />Fuel volume in gallons: <br />4, 03.8 <br />Model: <br />Water level in inches: <br />0.00 <br />S/N: <br />Test time: <br />21:15-00:25 <br />Open time in sec: <br />Number of thermisters: <br />5 <br />Holding psi: <br />Specific gravity: <br />0.734 <br />Resiliency cc: <br />Water table depth in inches: <br />Test leak rate ml/h: <br />Determined by (method): <br />NO WELL <br />Metering psi: <br />Leak rate in gph: <br />0.007 <br />Calib. leak in gph: <br />RESULT: <br />PASS <br />RESULT: <br />COMMENTS COMMENTS <br />NOTE THAT THERE IS NO WELL AT THIS <br />FACILITY. <br />i <br />ULLAGE TEST RESULTS <br />Test method: UTS-4 SYSTEM <br />Test time: oi:lo-o1:40 <br />Ullage volume: 1,297 <br />Ullage pressure: 2.50 <br />RESULT: PASS <br />DATA FOR UTS-4T ONLY: <br />Time of test 1: 01:10-01:20 <br />Temperature: 63.20 <br />Flow rate: 0.200-0.400 <br />Time of test 2: 01:20-01:30 <br />Temperature: 63.10 <br />Flow rate: 0.200-0.100 <br />Time of test 3: 01:30-01:40 <br />Temperature: 63.20 <br />Flow rate: 0.200-0.100 <br />COMMENTS <br />20000 MARINER AVE <br />LINE TEST RESULTS <br />GI I a R c r) <br />Material: <br />Diameter (in): <br />Length (in): <br />Test psi: <br />Bleedback cc: <br />Test start time <br />Test 1: start time: <br />finish psi: <br />vol change cc: <br />Test 2: start time: <br />finish psi: <br />vol change cc: <br />Test 3: start time: <br />finish psi: <br />vol change cc: <br />Final gph: <br />RESULT: <br />Test type: <br />Pump type: NONE Pump make: <br />CALIFORNIA 90503 <br />