Laserfiche WebLink
San Joaquin County <br /> ®PQ•u!N CEnvironmental Health DepartmentDIRECTOR <br /> O Donna Heran,RENS <br /> r. ,2600 EastiStreet <br /> a: PROGRAM COORDINATORS <br /> U): s { Stockton, California95202-3029Robert McClellon,RENS <br /> ® Jeff Carruesco,REHS, RDI <br /> ' Kasey Foley,REHS <br /> rq•. �"..�;�PWebsite: .sjov.org/e <br /> �ary 16, 2010 Phone: (209)468-3420 <br /> Fax: (209)464-0138 <br /> Mark Vendeiro <br /> MVP Petroleum Engineering, Inc. <br /> P.O. Box 281 <br /> Folsom, CA 95763-0281 <br /> Re: Country Club 76, 2575 Country Club Blvd, Stockton, CA 95204 SR0059302 <br /> The San Joaquin County Environmental Health Department(EHD) has completed the review of <br /> install Red Thread IIA penetration fittings art#012030-626-0 <br /> the application for a permit to p g (p ) <br /> on the underground storage tank (UST)system at the above noted address. Penetration fittings <br /> will be installed on the vent sump and 91 product piping sump. The permit has been approved <br /> with the following conditions: <br /> 1. Contact the local fire department and the San Joaquin Valley Air Pollution Control <br /> District for any applicable permits and requirements. <br /> 2. Any changes in information and scope of work must be submitted to EHD for approval <br /> prior to commencing work. All new addenda supersede the previous ones. <br /> 3. Contact Garrett Backus at(209) 468-2986 to arrange the following inspection <br /> appointments (a 48-hour notice is required for inspection appointments). <br /> a. Primary 91 product piping soap test: One hour pneumatic pressure test at 110% of <br /> operating pressure, or 40 psi, whichever is greater. <br /> b. Primary 87, 91, diesel vent piping soap test: One hour pneumatic pressure test at <br /> 110% of operating pressure, or 5 psi, whichever is greater. <br /> c. Secondary containment (91 piping and vent) sump soap test: One hour pressure test <br /> of the sump interstitial space per sump manufacturer's guidelines. If there are no <br /> manufacturer's guidelines, test shall be performed using an applicable method <br /> specified in an industry code or engineering standard. <br /> d. Secondary(91 product; 87, 91 and diesel vent) piping soap test: One hour pressure <br /> test per manufacturer's guidelines. If there are no manufacturer's guidelines, test <br /> shall be performed using an applicable method specified in an industry code or <br /> engineering standard. <br /> e. 24-hour hydrostatic test(or equivalent)on 91 piping and vent sumps, after backfill. <br /> Please be aware that the facility cannot operate the UST system prior to the EHD <br /> inspection and approval. <br /> t <br /> l <br />