My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
COUNTRY CLUB
>
2575
>
2300 - Underground Storage Tank Program
>
PR0231070
>
COMPLIANCE INFO_2012-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/22/2023 4:20:12 PM
Creation date
6/3/2020 9:43:36 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2018
RECORD_ID
PR0231070
PE
2351
FACILITY_ID
FA0006439
FACILITY_NAME
COUNTRY CLUB MOBIL CIRCLE K
STREET_NUMBER
2575
STREET_NAME
COUNTRY CLUB
STREET_TYPE
BLVD
City
STOCKTON
Zip
95204
CURRENT_STATUS
01
SITE_LOCATION
2575 COUNTRY CLUB BLVD
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2351_PR0231070_2575 COUNTRY CLUB_2012-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
391
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sjgov.org/ehd <br />gg. K� WMi <br />t <br />Facility Name: Facility Address: <br />Date: <br />Country Club Valero 2575 COUNTRY CLUB BLVD, Stockton <br />January 23, 2017 <br />1 -- - ------- ---- . <br />40 <br />-01-"K. <br />. .... ....... K <br />-- ------- t. <br />--p <br />Item # <br />Remarks <br />9 <br />CCR 2636(f)(1) Monitoring in sump UDC failed to activate an audible and visual alarm or stop the flow product. <br />The L18 sensor located in the UDC 3/4 sump failed to activate an audible and visual alarm when tested to ensure <br />continuous monitoring of the tank system. All monitoring equipment shall be maintained to activate an audible and <br />visual alarm or stop the flow of product at the dispenser when it detects a leak. Correct immediately by having a <br />properly licensed, trained, and certified contractor replace the failed component with a functional component (LG <br />113-x listed, if applicable) and obtain a permit within one business day from the EHD. If the failed component can't <br />be replaced immediately, there is a possibility that the impacted LIST system may be red tagged to prevent fuel <br />inputs. Submit proof of correction to the EHD. <br />This is a Class 11 violation. <br />316 <br />HSC 25290.1(c3), 25290.2(c3) Secondary containment not constructed to prevent water intrusion (after Jul 2003). <br />Water was found in following sumps: the diesel STP sump, vent sump (no gasket was available on the sump's lid), <br />87 -octane STP sump, UDC 1/2 (approximately 0.5-1 inches), and UDC 5/6. Secondary containment shall be <br />constructed to prevent any water intrusion into the system by precipitation, infiltration, or surface runoff. <br />Immediately remove all liquid, contact a properly licensed, trained, and certified contractor to address the water <br />intrusion into above sumps permit and inspection of the EHD. Submit proof of correction to the EHD. <br />This is a Class 11 violation. <br />318 <br />CCR 2636(f)(2) Leak detector failed to detect a 3.0 gph leak at 10 psi. <br />The diesel line leak detector failed to detect a leak when tested. All line leak detectors shall be capable of detecting <br />a 3 -gallon per hour leak at 10 psi. Immediately have a properly licensed, trained, and certified contractor repair or <br />replace the failed leak detector (LG 113-x listed, if applicable) and obtain a permit within one business day from the <br />EHD. If the failed leak detector can't be replaced immediately, there is a possibility that the diesel LIST system may <br />be red tagged to prevent fuel inputs. <br />This is a Class 11 violation. <br />320 <br />CCR 2635(b)(2) Overfill prevention system not present or failed to meet overfill requirements. <br />The ATG used as the overfill prevention system was not functional during testing. The ATG reset was activated and <br />ATG retested during the inspection with passing results. This was corrected on site. <br />This is a Class 11 violation. <br />Overall Inspection Comments: <br />An inspection checklist was provided to the facility operator on the day of inspection. The EHD has written the <br />complete report which replaces the initial checklist. <br />Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br />documenting the corrective actions that have been or will be taken for each violation, and any supporting <br />paperwork, within 30 days of receiving the complete inspection report. <br />NOTE: If the diesel spill container fails during operation or maintenance, they shall be replaced with a spill <br />FA0006439 PRO231070 SCO01 01/23/2017 <br />EHD 23-01 Rev. 09/22/16 Page 5 of 6 Underground Storage Tank Program OIR <br />
The URL can be used to link to this page
Your browser does not support the video tag.