Laserfiche WebLink
0 <br />0 <br />San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone. (209) 468-3420 Fax: (209) 468-3433 Web: www.A*gov.o[gLQbd <br />p mum <br />r <br />7 <br />Facility Name: Facility Address: <br />Date: <br />Country Club Valero 2575 COUNTRY CLUB BLVD, Stockton <br />January 23, 2017 <br />:i{ <br />M a" <br />72--il d <br />Item # <br />Remarks <br />209 <br />CCR 2715(c) Designated operator did not inspect all required items and/or the inspection reports not completed. <br />The following was noted at the time of inspection: <br />1. The designated operator (DO) failed to check and note the correct test dates for the spill container and leak <br />detector testing on the 2-26-2017, 3-14-2016, and 4-27-2016 designated operator monthly inspection reports. Test <br />dates were listed as 1-14-2015 instead of 1-29-2016. <br />2. On the 7-20-2016, 6-27-2016, and 5-25-2016 DO inspection reports, the L14 alarm was listed with no indication <br />when this alarm had occurred or if it was corrected. <br />3. On the 2-26-2016 DO inspection report, the S1 alarm (which occurred on 2-2-2016 and 2-7-2016) was not <br />documented. <br />4. On the 12-28-16 DO inspection report, the S-3 alarm was identified, however, no date when this alarm occurred <br />was provided. <br />5. On the 7-20-2016 DO inspection report, the L-19 alarm (which occurred on 7-18-2016) was not documented. <br />During the monthly inspection, the designated operator shall check that all required testing and maintenance for the <br />LIST system have been completed and document the dates they were done. Ensure that designated operators <br />performing monthly inspections at this facility are including all of the required information on the reports. <br />This is a Class 11 violation. <br />211 <br />CCR 2715(f) Designated operator employee training not performed or log not kept. <br />The designated operator employee training log was not kept, the employee hire dates for employees hired after <br />2005 was not maintained. The designated operator shall train facility employees for which he or she is responsible <br />in the proper operation and maintenance of the LIST system once every 12 months. Ensure that employees have <br />been trained by the designated operator, maintain the list on site, and submit a copy of the training records to the <br />EHD. The training log was corrected at the time of inspection. <br />This is a Class 11 violation. <br />305 <br />HSC 25290.1(e) VPH monitoring of the interstitial spaces of the LIST system is not maintained. <br />The following was noted at the time of inspection: <br />1) The communication (of the interstitial space and its sensor) inside the UDC 1/2 and UDC 3/4 failed when tested, <br />indicating that no continuous communication exists between the entire interstitial space and the existing brine <br />sensor. <br />2) The communication inside the 87 -octane diesel sump could not be tested due to a missing brine test port. <br />The underground tank system shall be designed and constructed with a continuous monitoring system capable of <br />detecting the entry of the liquid- or vapor -phase of the hazardous substance stored in the primary containment into <br />the secondary containment and capable of detecting water intrusion into the secondary containment. Also, the <br />sensors monitoring the liquid level in the interstitial space shall be maintained so that a breach in the primary or <br />secondary containment is detected before the hazardous substance is released into the environment. Correct <br />immediately by having a properly licensed, trained, and certified contractor investigate and correct the failed <br />component with a functional component, obtain a permit from the EHD, as needed. Immediately correct and <br />submit proof of correction to the EHD. <br />This is a Class 11 violation. <br />FA0006439 PR0231070 SC001 01/23/2017 <br />EHD 23-01 Rev. 09/22116 Page 4 of 6 Underground Storage Tank Program OIR <br />