My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
COUNTRY CLUB
>
2575
>
2300 - Underground Storage Tank Program
>
PR0231070
>
COMPLIANCE INFO_2012-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/22/2023 4:20:12 PM
Creation date
6/3/2020 9:43:36 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2018
RECORD_ID
PR0231070
PE
2351
FACILITY_ID
FA0006439
FACILITY_NAME
COUNTRY CLUB MOBIL CIRCLE K
STREET_NUMBER
2575
STREET_NAME
COUNTRY CLUB
STREET_TYPE
BLVD
City
STOCKTON
Zip
95204
CURRENT_STATUS
01
SITE_LOCATION
2575 COUNTRY CLUB BLVD
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2351_PR0231070_2575 COUNTRY CLUB_2012-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
391
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 SAN JOAQUIN COUNTY • <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />600 East Main Street, Stockton, California 95202-3029 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sogov.o[g/ehd/unitiii.htmi <br />CONTINUATION FORM <br />Page: 4 of 5 <br />OFFICIAL INSPECTION REPORT <br />Date: 01/30/12 <br />Facility Address: 2575 Country Club Blvd <br />Program: UST <br />SUMMARY OF VIOLATIONS <br />CLASS 1, CLASS 11, or MINOR -Notice to Comply) <br />204. The designated operator failed to document all the alarms from the attached alarm history on the <br />2011 designated operator monthly inspection reports and failed to check that they were responded to <br />appropriately. The missing alarms include: <br />L2- 87 STP sump annular sensor - fuel alarm - 8-12-11 <br />L5- 91 STP sump sensor - fuel alarm - 6-15-11 <br />L6- 91 STP sump annular sensor - fuel alarm - 11-8-11 <br />L8- 91 fill sump annular sensor - fuel alarm - 12-22-11 <br />L14 - vent sump annular sensor - fuel alarm - 1-22-12 <br />L16 - dispenser 1/2 sump annular sensor - fuel alarm - 9-12-11, 11-14-11 <br />L20 - dispenser 5/6 sump annular sensor - fuel alarm - 10/11/11 <br />S1 - 87 product vacuum sensor - no vacuum alarm - 12/20/11, 1/1/12 <br />S2 - 87 tank annular vacuum sensor - no vacuum alarm - 6/23/11 <br />S4 - 91 tank annular vacuum sensor - no vacuum alarm - 4/5/11 <br />During the monthly inspection, the designated operator shall review the alarm history for the previous <br />month, check that each alarm was documented and responded to appropriately, and attach a copy of <br />the alarm history with documentation taken in response to any alarms to the monthly report. Ensure that <br />designated operators performing monthly inspections at this facility are including all of the required <br />information on the reports. <br />305, 405. The 87 product fill sump liquid sensor failed when tested. The continuous monitoring system <br />shall be maintained to detect the entry of the liquid or vapor phase of the hazardous substance stored in <br />the primary containment into the secondary containment and to detect water intrusion into the secondary <br />containment. Correct immediately by having a properly licensed, trained, and certified contractor <br />replace the failed component with a functional component (LG 113-x listed, if applicable) and obtain a <br />permit within one business day from the EHD. If the failed component can't be replaced immediately, <br />there is a possibility that the 87 product UST system may be red tagged to prevent fuel inputs. <br />ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br />THIS FACILITY IS SUBJECT TO REINSPECT T ANYPME AT EHD'S CURRENT HOURLY RATE. <br />EHD Inspector: <br />Garrett Backus (209) 468-2986 <br />Re iv Y: D <br />Title: <br />EHD 23-02-003 Rev 07/12/11 CONTINUATION FORM <br />
The URL can be used to link to this page
Your browser does not support the video tag.