Laserfiche WebLink
Page 1 of 3 <br /> Michelle Henry [EH] <br /> From: Michelle Henry [EH] <br /> Sent: Thursday, December 27, 2007 8:13 AM <br /> To: 'Dejan Ristic' <br /> Subject: RE: Lodi Memorial Hospital Plan Check <br /> Dejan, <br /> Thanks for the quick response. Please provide the exact part number for the spillbucket you will be using. I also <br /> need UL, ULC or 3rd party listing information for all tanks, piping and equipment, i.e. monitoring equipment, <br /> overspill containment device, overfill protection device, dispenser pan, etc. that will be used for this project. <br /> Thanks <br /> Michelle <br /> From: Dejan Ristic [mailto:dejanr@westernpump.com] <br /> Sent: Wednesday, December 26, 2007 12:06 PM <br /> To: Michelle Henry [EH] <br /> Cc: Hopper, Dave; Diana Sanchez; Ryan Rethmeier; Mark Bridgwater; Michael Mizicko; John Borchardt <br /> Subject: RE: Lodi Memorial Hospital Plan Check <br /> Hello Michelle: <br /> It was a pleasure talking with you earlier today. Thanks for your help. <br /> 1. Please refer to our drawing GP-00 UST EQUIPMENT LIST, Sym 25: Veeder-Root <br /> Sensor No. 794380-303 is, in deed, a dual-point hydrostatic sensor for DWT6 <br /> tank and is the actual unit we will be installing for tank interstitial space <br /> monitoring (I am attaching Veeder Root Manual No. 576013-795, p. 3 for your <br /> reference) . <br /> I hope this addresses the sensor issue. <br /> 2. OPW 511 - Sorry for the confusion as we mistakenly inserted Series 700 cut <br /> sheet. Attached please find the 500 Series information. Attached please find <br /> correct cut sheet - we intend to use single port configuration. <br /> Please let me know if either of the above requires more information or <br /> clarification. <br /> 3. In regards to the existing tank please note that we have just been advised <br /> by our general contractor that the existing tank is being used for the current <br /> central plant and will remain on-line. The existing lines will not connect to <br /> the new system. <br /> Thank you very much for giving us advance information on any adjustments <br /> needed in the plans as this will contribute in making sure that we address all <br /> issues and reduce the time needed to process the plan check. Should you <br /> notice any other issues please let us know so that we can take care of them <br /> and, hopefully, have the plan check approved as soon as possible. <br /> Thank you very much for trying to expedite. <br /> 1/28/2008 <br />