Laserfiche WebLink
Fiber Glass Systems- Y Bulletin B2,02 <br /> May 1,2006 <br /> STAR - SMITH • FIBERCAST UL/ULC Listed Red Thread%A Piping System <br /> 3 General Specifications <br /> Primary Piping <br /> W&IZQN I-Scope <br /> This section covers the use of fiberglass reinforced machined areas shall be protected from sunlight until <br /> plastic (FRP) pipe for single wall fuel handling and installed. <br /> fuel handling vent and vapor applications including 2.06 Acceptable Manufacturers. Fiber Glass <br /> gasoline, unleaded gasoline, gasollne/alcohol Systems, Smith Fibercast, 501-618-2203,or approved <br /> mixtures, bio-diesel and diesel up to 150°F and 250 equal. <br /> psig cyclic pressure. <br /> Section 3-Material and Construction <br /> ,�EQT/Q�f - General Condi(Q�� 3.01 2"-4" Pike. The pipe shall be manufactured by <br /> 2.01 Coordination. Material furnished and work the filament winding process using an amine cured <br /> performed under this section shall be coordinated with epoxy thermosetting resin to impregnate strands of <br /> the related work and equipment specified under other continuous glass filaments, which are wound around <br /> sections, i.e.Valves, Flexible Connectors, Equipment, a mandrel at a 54314" winding angle under controlled <br /> tension. The pipe shall be heat cured and the cure <br /> 2.02 Governing Standards. Except as mofidifed or shall be confirmed using a Differential Scanning <br /> supplemented herein, all materials and construction Calorimeter. <br /> methods shall comply with and be tested in Pipe shall be supplied with a T.A.B.Tm (Threaded <br /> accordance with the following standards and test and Bonded)ends. <br /> methods: Pipe shall have a minimum continuous cyclic <br /> Standards and Test Methods pressure rating of 125 psig at 150°F in accordance <br /> UL971-2004 Standard for Nonmetallic with ASTM D2992, Procedure A or UL 971 pressure <br /> Underground Piping for Flammable rating. <br /> Liquids All pipe shall be 100% hydrotested at the factory <br /> ASTM D2310 Standard Classification for Machine- before shipment at a minimum pressure of 265 psig <br /> Made "Fiberglass" (Glass Fiber and shall be UL971-2004 Listed and labeled. <br /> Reinforced Thermosetting Resin) 3.02 ASTM D2310 Classifications (at 73.4°F) <br /> Pipe 211 -31' RTRP-11AF <br /> ASTM D2992 Standard practice for obtaining 411 RTRP-11AH <br /> Hydrostatic or Pressure Design Basis <br /> for "Fiberglass" (Glass Fiber Reinf-for properties cell classifications shown are <br /> orced Thermosetting Resin) Pipe and minimums.) <br /> Fittings 3.03 Fittinas. All fittings shall be manufactured <br /> using the same type of material as the pipe. Fittings <br /> �„0�3 ,Ql{�ratina Conditions. In addition to the may be manufactured either by compression molding, <br /> filament winding, resin transfer molding or contact <br /> above listed minimum design requirements, the molding methods. All fittings, adapter, and sump <br /> system shall meet the following minimum operating penetrations shall be UL971-2004 Listed. <br /> conditions:a. Operating Pressure Fittings shall be adhesive bonded matched tapered <br /> heli and spigot. <br /> b. Fluid Conveyed 3.04 Connections. Connections to flex connectors <br /> c. Test Pressure or other piping materials shall be made by the use <br /> of NPT (National Pipe Thread) threaded adapters or <br /> 2.04 Quality Assurance. Pipe manufacturer's flanges bonded to the FRP piping system. <br /> quality program shall be in compliance with ISO 9001 3.05 Sump P2netrations. Sump penetrations shall <br /> and/or API Q1. be made by means of a permanently bonded FRP <br /> coupling. The coupling shall be capable of adjusting <br /> 2.05 Delivery. Storage. and Handling. Pipe and for the slope of the piping system entering or exiting <br /> fittings shall be protected from damage due to impact the sump wall, <br /> and point loading. Pipe shall be properly supported to 3.06 Adhesives. Adhesives shall be manufacturer's <br /> avoid damage due to flexural strain. The contractor standard for the piping system specified. <br /> shall not allow dirt, debris or other extraneous 3.07 Acceptable Products. RED THREAD IIA <br /> materials to get into pipe and fittings. All factory Piping System as manufactured by FGS Smith <br /> Fibercast or engineered approved equal. <br /> 0 Trademark of Varco I/R Inc. FIBER GLASS SYSTEMS•A NATIONAL OILWELL VARCO COMPANY <br /> http:/lwww.smithfibercast,com 2700 W.65th ST.,LITTLE ROCK,AR 72209.501-568-4010-FAX 501-568-4465 <br /> 25 S.MAIN ST.,SAND SPRINGS,OK 74063•918-245-6651 •FAX 918-245-7566 <br />