Laserfiche WebLink
0 6 <br /> San Joaquin County <br /> Environmental Health Department DIRECTOR <br /> Donna Heran, REHS <br /> 1868 East Hazelton Avenue <br /> Stockton, California 95205-6232 PROGRAM COORDINATORS <br /> Robert McClellon,REHS <br /> Jeff Carruesco,REHS,RDI <br /> qui Website: www.S/gov.org1ehd Kasey Foley,REHS <br /> -F--0- Linda Turkatte, REHS <br /> Phone: (209)468-3420 Rodney Estrada, REHS <br /> Fax: (209)464-0138 Adrienne Ellsaesser,REHS <br /> August 1, 2013 <br /> Kim White <br /> Elite IV Contractors <br /> 2535 Wigwam Dr. <br /> Stockton, CA 95205 <br /> Re: Lodi Memorial Hospital 975 S. Fairmont Ave. Lodi, CA 95240 Revised SR0067540 <br /> The San Joaquin County Environmental Health Department (EHD) has completed the review of <br /> the application for a permit to replace the electrical penetration in the diesel transition remote fill <br /> sump with a Diversified Products Manufacturing penetration repair kit MSZ BLS 1.1 on the <br /> underground storage tank (UST) system at the above noted address. An addendum has been <br /> received to include removing a 3' x 3'section of cement in front of the diesel transitional sump to <br /> expose the electrical penetration on the outside of the sump and replace it with a new electrical <br /> penetration. The addendum also includes removing a 3' x 3' section of cement next to the Vent <br /> transition sump so that the electrical penetration can be replaced on the outside and inside of <br /> the sump. The permit has been approved with the following conditions: <br /> 1. Contact the local fire department and the San Joaquin Valley Air Pollution <br /> Control District for any applicable permits and requirements. <br /> 2. Any changes in information and scope of work must be submitted to EHD for <br /> approval prior to commencing work. All new addenda supersede the previous <br /> ones. <br /> 3. Contact Aris Cacapit at (209) 468-3453 to arrange the following inspection <br /> appointments (a 48-hour notice is required for inspection appointments). Please <br /> be aware that inspections for emergency work must be scheduled within five <br /> .days of permit approval. <br /> a. Visual inspection: Monitoring system must be verified for all functions normal and <br /> that there are no brine leaks after the repair. <br /> 4. Qualified service technicians must possess or work under the direct and personal <br /> supervision of an individual physically present at the work site who possesses all <br /> of the following: <br /> a. One of several permissible valid, current contractor's licenses issued by the <br /> Contractors State License Board (may be issued to the installation company), or a <br /> Tank Tester's license issued to the individual by the State Water Board, and <br /> b. A valid, current California UST Service Technician certificate issued by the <br /> International Code Council (ICC), and <br />