My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2011-2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
B
>
BENJAMIN HOLT
>
2908
>
2300 - Underground Storage Tank Program
>
PR0231021
>
COMPLIANCE INFO_2011-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/22/2022 2:32:40 PM
Creation date
6/3/2020 9:44:28 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011-2015
RECORD_ID
PR0231021
PE
2361
FACILITY_ID
FA0003625
FACILITY_NAME
ARCO STATION #83560*
STREET_NUMBER
2908
Direction
W
STREET_NAME
BENJAMIN HOLT
STREET_TYPE
DR
City
STOCKTON
Zip
95207
APN
09763032
CURRENT_STATUS
01
SITE_LOCATION
2908 W BENJAMIN HOLT DR
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231021_2908 W BENJAMIN HOLT_2011-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
394
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 Page-2_of_2 <br /> 6. PIPING SUMEP TESTING <br /> Test Method Developed By: ❑Sump Manufacturer ®Industry Standard ❑Professional Engineer <br /> ❑Other(Spec6) <br /> Test Method Used: ❑Pressure ❑Vacuum ®Hydrostatic' <br /> ❑Other(Spec) <br /> Test Equipment Used:INCON SUMP TESTER Equipment Resolution:+I-0.002" <br /> Sump#LTC Sump# Sump# Sump# <br /> Sump Diameter: 48" <br /> Sump Depth: 53.50" <br /> Sump Material: FIBERGLASS <br /> Height from Tank Top to Top of 33" <br /> Highest Piping Penetration: <br /> Height from Tank Top to Lowest 20„ <br /> Electrical Penetration: <br /> Condition of sump prior to testing: DRY <br /> Portion of Sump Tested' ABOVE <br /> PENETRATIONS <br /> Does turbine shut down when <br /> sump sensor detects liquid(both ❑Yes [:]No ®NA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA ❑Yes ❑No [INA <br /> product and water)?* <br /> Turbine shutdown response time NIA <br /> Is system programmed for fail-safe ❑ ®NA ❑Yes ❑NA ❑yes <br /> shutdown?* <br /> E]Yes No ❑No ❑No ❑NA [_1 Yes El No ❑NA <br /> Was fail-safe verified to be Cj Yes ❑No ®NA ❑Yes ❑No ❑NA []Yes ❑No ❑NA [:]Yes ❑No [:INA <br /> o erational?* <br /> Wait time between applying <br /> pressure/vacuum/water and starting 10 MIN <br /> test: <br /> Test Start Time: 10:06 AM <br /> Initial Reading(RI): 4.9196" <br /> Test End Time: 10:21 AM <br /> Final Reading(RF): 4.9193" <br /> Test Duration: 15 MIN <br /> Change in Reading(RF-RI): -0.0003" <br /> Pass/Fail Threshold or Criteria: +l-0.002" +/-0.00211 +l-0.002" +l-0.002" <br /> Test Result: 'Rpass 0yFat1 ❑;Pass ❑TaIL' ❑,Pass ❑Fail. LSI, ss C�Fai1' <br /> Was sensor removed for testing? ®Yes ❑No ❑NA [:]Yes ❑No [INA ❑Yes [:]No ❑NA ❑Yes ❑No ❑NA <br /> Was sensor properly replaced and SNA ®yes [:]No ❑NA ❑Yes ❑ ❑ ❑Y <br /> verified functional after testing? ®Yes ❑No No NA es ❑No ❑NA <br /> Comments—(include fn ormafion on repairs made prior to testin , and recommended follow- yr ailed tests) <br /> ABOVE IS THE LAST OF TWO BACK TO BACK 15 MINUTE TESTS <br /> I If the entire depth of the sump is not tested,specify how much was tested. If the answer to any of the;questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire sump must be tested. (See SWRCB LG-160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.