My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2011-2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
B
>
BENJAMIN HOLT
>
2908
>
2300 - Underground Storage Tank Program
>
PR0231021
>
COMPLIANCE INFO_2011-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/22/2022 2:32:40 PM
Creation date
6/3/2020 9:44:28 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011-2015
RECORD_ID
PR0231021
PE
2361
FACILITY_ID
FA0003625
FACILITY_NAME
ARCO STATION #83560*
STREET_NUMBER
2908
Direction
W
STREET_NAME
BENJAMIN HOLT
STREET_TYPE
DR
City
STOCKTON
Zip
95207
APN
09763032
CURRENT_STATUS
01
SITE_LOCATION
2908 W BENJAMIN HOLT DR
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231021_2908 W BENJAMIN HOLT_2011-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
394
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• i <br /> D. Results of Testing/Servicing <br /> Complete the following checklist: <br /> Software Version Installed:332.00 <br /> ®Yes ❑No* Is the audible alarm operational? <br /> ®Yes ❑No* Is the visual alarm operational? <br /> ®Yes ❑No* Is the print function operational? <br /> ®Yes ❑No* Were all sensors visually inspected,functionally tested,and confirmed operational? <br /> ®Yes ❑ No* Were all sensors installed at lowest point of secondary containment and positioned so that other <br /> equipment will not interfere with their proper operation? <br /> ®Yes ❑No* If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. <br /> ❑N/A modem)operational? <br /> ®Yes ❑No* For pressurized piping systems, does the turbine automatically shut down if the piping secondary <br /> ❑N/A containment monitoring system detects a leak, fails to operate, or is electrically disconnected? If <br /> yes: which sensors initiate positive shutdown? (Check all that apply) ® Sump Sensors; <br /> Dispenser Containment Sensors. <br /> Did you confirm positive shutdown due to leaks and sensor failure/disconnection? ®Yes; ❑ No. <br /> ® ❑No* For tank systems that utilize the monitoring system as the primary tank overfill warning device, is <br /> ❑N/A the overfill warning alarm visible and audible at the tank fill point(s) and operating properly? At <br /> Yes what percent of tank capacity does the alarm trigger? 90% <br /> L1 Yes* ENK No Was any monitoring equipment replaced? If yes, identify specific sensors, probes, or other <br /> equipment replaced and list the manufacturer name and model for all replacement parts in Section <br /> E, below. <br /> ®Yes* ❑No Was liquid found inside any secondary containment systems designed as dry systems? (Check all <br /> that apply)❑ Product;❑Water. If yes,describe causes in Section E,below. <br /> Yes ❑No* Was monitoring system set-up reviewed to ensure proper settings? Attach set up reports, if <br /> applicable <br /> ®Yes 1 ❑No* Is all monitoring equipment operational per manufacturer's specifications? <br /> E. Comments: Water was found in the 91 Fill Sump.Removed and disposed of water found in the 91 <br /> Fill Sump. <br />
The URL can be used to link to this page
Your browser does not support the video tag.