Laserfiche WebLink
SWRCB, January2002 0 Page _4_ of —8- <br />6. PIPING SUMP TESTING <br />Test Method Developed By: ❑ Sump Manufacturer ® Industry Standard ❑ Professional Engineer <br />❑ Other (Spec) <br />Test Method Used: ❑ Pressure ❑ Vacuum ® Hydrostatic <br />❑ Other (Specify) <br />Test Equipment Used: INCON SUMP TESTER <br />Equipment Resolution: + / - 0.002" <br />Sump Diameter: <br />Sump # 87(1) <br />Sump # 87(2) <br />Sump # 91(3) <br />Sump # PIPING <br />SUMP <br />48" <br />48" <br />48" <br />48" <br />Sump Depth: <br />44" <br />42" <br />58" <br />24" <br />Sump Material: <br />FIBERGLASS <br />FIBERGLASS <br />FIBERGLASS <br />FIBERGLASS <br />Height from Tank Top to Top of <br />Highest Piping Penetration: <br />17" <br />19" <br />15" <br />19" <br />Height from Tank Top to Lowest <br />Electrical Penetration: <br />8„ <br />14" <br />14.50" <br />18.50" <br />Condition of sump prior to testing: <br />DRY <br />DRY <br />DRY <br />DRY <br />Portion of Sump Tested' <br />ABOVE <br />PENETRATION <br />ABOVE <br />PENETRATION <br />ABOVE <br />PENETRATION <br />ABOVE <br />PENETRATION <br />Does turbine shut down when <br />sump sensor detects liquid (both <br />product and water)?* <br />®Yes [--]No ❑NA <br />®Yes ❑ No [:INA <br />®Yes [:]No ❑NA <br />® Yes ❑ No ❑ NA <br />Turbine shutdown response time <br />3 SEC <br />3 SEC <br />3 SEC <br />3 SEC <br />Is system programmed for fail-safe <br />shutdown?* <br />®Yes ❑ No ❑ NA <br />® Yes ❑ No [:INA <br />® Yes ❑ No ❑ NA <br />®Yes ❑ No ❑ NA <br />fail-safe <br />Was fail-safe verified to be <br />operational?* <br />® Yes ❑ No ❑ NA <br />® Yes ❑ No ❑ NA <br />® Yes ❑ No ❑ NA <br />®Yes ❑ No ❑ NA <br />Wait time between applying <br />pressure/vacuum/water and starting <br />test: <br />10 MIN <br />10 MIN <br />10 MIN <br />10 MIN <br />Test Start Time: <br />10:34 AM <br />11:35 AM <br />10:34 AM <br />11:17 AM <br />Initial Reading (Rt): <br />7.5091" <br />7.2440" <br />6.6773" <br />1.7361" <br />Test End Time: <br />10:49 AM <br />11:50 AM <br />10:49 AM <br />11:32 AM <br />Final Reading (RF): <br />7.5074" <br />7.2443" <br />6.6772" <br />1.7361" <br />Test Duration: <br />15 MIN <br />15 MIN <br />15 MIN <br />15 MIN <br />Change in Reading (RF -R,): <br />-0.0017" <br />0.0003" <br />-0.000111 <br />0.0001' <br />Pass/Fail Threshold or Criteria: <br />+/- 0.002" <br />+/. 0..y0�y02" <br />+/-0.00211 <br />+/- 0.0012" <br />Y <br />y� <br />Was sensor removed for testing? <br />® Yes ❑ No ❑ NA <br />® Yes ❑ No ❑ NA <br />®Yes ❑ No ❑ NA <br />® Yes ❑ No ❑ NA <br />Was sensor properly replaced and <br />verified functional after testing? <br />®Yes ❑ No ❑ NA <br />®Yes ❑ No []NA <br />®Yes ❑ No [:INA <br />®Yes [:]No ❑ NA <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />ABOVE IS THE LAST OF TWO BACK TO BACK 15 MINUTE TESTS <br />ABOVE PIPING SUMP IS A "LIQUID TRAP SUMP" <br />PRODUCT SECONDARY LINES ENTER FROM TANK SUMP AND LEAVE AND GO TOWARDS UDC'S <br />' If the entire depth of the sump is not tested, specify how much was tested. If the answer to any of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire sump must be tested. (See SWRCB LG -160) <br />