SWRCB January 2002 <br />8. <br />0 <br />FILL RISER CONTAINMENT SUMP TESTING <br />Page _6_ of —8- <br />Facility is Not Equipped With Fill Riser Containment Sumps ❑ <br />Fill Riser Containment Sumps are Present, but were Not Tested ❑ <br />Test Method Developed By: <br />❑ Sump Manufacturer ® Industry Standard ❑ Professional Engineer <br />❑ Other (Spec) <br />Test Method Used: <br />❑ Pressure <br />❑ Other (Spec) <br />❑ Vacuum <br />® Hydrostatic <br />Test Equipment Used: INCON SUMP <br />TESTER <br />Equipment Resolution: + / - 0.002" <br />...Sump Diameter: <br />Fill Sump # <br />87(l) <br />MENEM <br />Fill Sump # <br />87 2 <br />Fill Sump # <br />91 3 <br />Fill Sump # <br />87(1) TLM <br />48" <br />48" <br />48" <br />48" <br />Sump Depth: <br />41.50" <br />42" <br />61.50" <br />37" <br />Height from Tank Top to Top of <br />Highest Piping Penetration: <br />N/A <br />N/A <br />N/A <br />N/A <br />Height from Tank Top to Lowest <br />Electrical Penetration: <br />17" <br />16" <br />14" <br />N/A <br />Condition of sump prior to <br />testing: <br />DRY <br />DRY <br />DRY <br />DRY <br />Portion of Sump Tested <br />ABOVE <br />PENETRATION <br />ABOVE <br />PENETRATION <br />ABOVE <br />PENETRATION <br />ABOVE <br />PENETRATION <br />Sump Material: <br />FIBERGLASS <br />FIBERGLASS <br />FIBERGLASS <br />FIBERGLASS <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test: <br />10 MIN <br />10 MIN <br />10 MIN <br />10 MIN <br />Test Start Time: <br />11:17 AM <br />11:17 AM <br />10:34 AM <br />10:34 AM <br />Initial Reading (RI): <br />3.2279" <br />2.2261 " <br />7.4400" <br />3.1058" <br />Test End Time: <br />11:32 AM <br />11:32 AM <br />10:49 AM <br />10:49 AM <br />Final Reading (RF): <br />3.2278" <br />2.2260" <br />7.4399" <br />3.1058" <br />Test Duration: <br />15 MIN <br />15 MIN <br />15 MIN <br />15 MIN <br />Change in Reading (RF -RI): <br />-0.0001" <br />-0.0001" <br />-0.0001" <br />0.000" <br />Pass/Fail Threshold or Criteria: <br />+/-0.00211 <br />+/-0.00211 <br />+/- 0.002" <br />+/-0.002" <br />Is there a sensor in the sum ? <br />® Yes ❑ No <br />❑ Fail <br />® Yes ❑ No <br />® .. .❑ Fail <br />® Yes ❑ No <br />ls.. <br />® Yes ❑ No <br />Does the sensor alarm when <br />either product or water is <br />detected? <br />No <br />®Yes ❑ []NA <br />®Yes ❑ No []NA <br />NA <br />®Yes [:]E]❑ <br />®Yes NA <br />No El <br />Was sensor removed for testing? <br />® Yes ❑ No ❑ NA <br />® Yes [:]No ❑NA <br />® Yes ❑ No [:INA <br />®Yes ❑ No ❑ NA <br />Was sensor properly replaced and <br />verified functional after testing? <br />®Yes [:]No ❑ NA <br />®Yes ❑ No ❑ NA <br />®Yes ❑ No ❑ NA <br />® Yes ❑ No ❑ NA <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />ABOVE IS THE LAST OF TWO BACK TO BACK 15 MINUTE TESTS <br />