My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2011-2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
B
>
BENJAMIN HOLT
>
2908
>
2300 - Underground Storage Tank Program
>
PR0231021
>
COMPLIANCE INFO_2011-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/22/2022 2:32:40 PM
Creation date
6/3/2020 9:44:28 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011-2015
RECORD_ID
PR0231021
PE
2361
FACILITY_ID
FA0003625
FACILITY_NAME
ARCO STATION #83560*
STREET_NUMBER
2908
Direction
W
STREET_NAME
BENJAMIN HOLT
STREET_TYPE
DR
City
STOCKTON
Zip
95207
APN
09763032
CURRENT_STATUS
01
SITE_LOCATION
2908 W BENJAMIN HOLT DR
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231021_2908 W BENJAMIN HOLT_2011-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
394
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
go <br />Facility #: <br />Address: <br />City, State: <br />2133 Date: <br />2908 BENJAMIN HOLT <br />STOCKTON, CA 95207 <br />Testing Information <br />04/19/11 <br />Comments: I ONLY TESTED 91 LEAK DETECTOR ONLY WITH VMI TESTER AS PER INSPECTOR <br />ALL OK. <br />Note: Pass = Leak detector reads leak and meters line. <br />Fail = Leak detector did not read leak. <br />This letter certifies that the annual leak detector tests were performed at the above referenced facility according to the equipment <br />manufacturers procedures and limitations and the results as listed are to my knowledge true and correct. The mechanical leak test <br />detector test pass/fail is determined using a low flow threshold trip rate of 3 gph at 10 PSI. <br />Inspected By: Contractor FASTECH - Fueling & Services Technologies, Inc. <br />Technician: Marco Godoy Lic#: A24199 <br />Signature: <br />1 <br />2 <br />3 <br />4 <br />5 <br />Product: <br />Manufacturer <br />Leak Detector Serial Number <br />Leak Detector Model No. <br />Full Operating Pressure (psi): <br />Test Leak Rate (ml/min)(gph) <br />Bleed Back Rate (ml): <br />Turbine Holding Pressure (psi): <br />Metering Pressure (psi): <br />Open/ Trip Time (mechanical only): <br />Pass / Fail <br />91 <br />VMI <br />N/A <br />LD2000 <br />32 <br />3.00 <br />85 <br />18 <br />14 <br />4SEC <br />PASS <br />Comments: I ONLY TESTED 91 LEAK DETECTOR ONLY WITH VMI TESTER AS PER INSPECTOR <br />ALL OK. <br />Note: Pass = Leak detector reads leak and meters line. <br />Fail = Leak detector did not read leak. <br />This letter certifies that the annual leak detector tests were performed at the above referenced facility according to the equipment <br />manufacturers procedures and limitations and the results as listed are to my knowledge true and correct. The mechanical leak test <br />detector test pass/fail is determined using a low flow threshold trip rate of 3 gph at 10 PSI. <br />Inspected By: Contractor FASTECH - Fueling & Services Technologies, Inc. <br />Technician: Marco Godoy Lic#: A24199 <br />Signature: <br />
The URL can be used to link to this page
Your browser does not support the video tag.