Laserfiche WebLink
RECERIED <br /> SWRCB,January 2002 7.UNDER-DISPENSER CONTAINMENT DC)TESTIN <br /> Test Method Developed By: F UDC Manufacturer F Industry Standard F Professional Engineer <br /> Other(Specify) <br /> Test Method Used By: F Pressure r vacuum 5_0 Hydrostatic <br /> r Other(Specify) I ML I TLr <br /> Test Equipment Used:VPLT ui ment Resolut ,'g <br /> r UDC ' 1 TDC#FI4 <br /> UDC Manufacturer: gilbarco gilbarco gilbarco gilbarco <br /> UDC Material: Fiberglass Fiberglass Fiberglass Fiberglass <br /> UDC Depth: 30.00 30.00 30.00 30.00 <br /> Height from UDC Bottom to Top 11.00 11.00 11.00 11.00 <br /> of Highest Piping Penetration: <br /> Height from UDC Bottom to <br /> Lowest Electrical Penetration: 17.00 17.00 17.00 17.00 <br /> Condition of UDC prior to good good good good <br /> testing: <br /> Portion of UDC Tested' 13 13 13 13 <br /> Does turbine shut down when <br /> UDC sensor detects liquid(both r Yes G No r NA t+ Yes r No r NA tt Yes r Nor NA 0 Yes f No r NA <br /> product and water)?* <br /> Turbine shutdown response time 02:00:00 sec 02:00:00 sec 02:00:00 sec 02:00:00 sec <br /> Is system programmed for fail- tf Yes f" Nor NA r Yes r No(r NA for Yes 4'r No C NA ro Yes r No d"r NA <br /> safe shutdown?* <br /> Was fail-safe verified to be t* Yes n No C NA 0 Yes r No f NA ro Yes r No C NA ro Yes r No r7 NA <br /> operational?* <br /> Wait time between applying <br /> pressure/vacuum/water and 5 min 5 min 5 min 5 min <br /> starting test <br /> Test Start Time: 13:31:00 13:09:00 13:31:00 13:09:00 <br /> Initial Reading(RI): 0.00000 in. 0.00000 in. 0.00010 in. 0.00100 in. <br /> Test End Time: 13:46:00 13:24:00 13:46:00 13:24:00 <br /> Final Reading(RF): 0.00000 in. 0.00000 in. 0.00010 in. 0.00100 in. <br /> Test Duration: 15 min 15 min 15 min 15 min <br /> Change in Reading(RF-RI): 0.00000 in. 0.00000 in. 0.00000 in. 0.00000 in. <br /> Pass/Fail Threshold or Criteria: +/-0.00200 +/-0.00200 +/-0.00200 +/-0.00200 <br /> Re '► r. Pass _Pss�.. 1? ss Pass' <br /> Was sensor removed for testing? 0 Yes G' Nor NA r Yes f"- No OF NA r Yes r No h" NA G Yes r Nor NA <br /> Was sensor properly replaced and t+ Yes C Nor NA 1* Yes r7 Nor NA ro Yes r Nor NA C Yes C Nor NA <br /> verified functional after testing? <br /> Comments—(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> 1 If the entire depth of the UDC is not tested,specify how much was tested.If the answer to any of the questions indicated with an asterisk(*)is"NO"or"NA",the entire UDC must <br /> be tested. <br /> WO:2319172 <br />