0 ECEIVED <br />SWRCB, January 2002 �&e2Wi <br />7. UNDER -DISPENSER CONTAINMENT (UDQ TESTING <br />Test Method Developed By: r- UDC Manufacturer Fi Industry Standard F Profek"WHU MENTA <br />r Other (SpecLfyj H-FALTH DERARIM 4T <br />Test Method Used By: F Pressure F, Vacuum WO Hydrostatic <br />F Other (Specify) <br />Test E2uiEment Used: VPLT <br />Equipment Resolution: 0.00001 in. <br />UDC Manufacturer: <br />UDC #112. <br />gilbarco <br />-D <br />gilbarco <br />J DC #5/6 <br />gilbarco <br />UDC #7/8 <br />gilbarco <br />UDC Material: <br />Fiberglass <br />Fiberglass <br />Fiberglass <br />Fiberglass <br />UDC Depth: <br />30.00 <br />30.00 <br />30.00 <br />30.00 <br />Height from UDC Bottom to Top <br />of Highest Pi in Penetration: <br />11.00 <br />11.00 <br />11.00 <br />11.00 <br />Height from UDC Bottom to <br />Lowest Electrical Penetration: <br />17.00 <br />17.00 <br />17.00 <br />17.00 <br />Condition of UDC prior to <br />testing: <br />good <br />good <br />good <br />good <br />Portion of UDC Tested' <br />13 <br />13 <br />13 <br />13 <br />Does turbine shut down when <br />UDC sensor detects liquid (both <br />product and water)?* <br />0 Yes r Nor NA <br />ro Yes r No r NA <br />0 Yes r" Nor NA <br />r, Yes r Nor NA <br />Turbine shutdown response time <br />02:00:00 see <br />02:00:00 see <br />02:00:00 see <br />02:00:00 see <br />Is system programmed for fail- <br />safe shutdown?* <br />0 Yes r No r NA <br />ro Yes r Nor NA <br />ro Yes r No r NA <br />r, Yes r' Nor NA <br />Was fail-safe verified to be <br />operational?* <br />ro Yes r No r NA <br />ro Yes r Nor NA <br />r, Yes r Nor NA <br />ro yes r Nor NA <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test <br />5 min <br />5 min <br />5 min <br />5 min <br />Test Start Time: <br />12:17:00 <br />11:55:00 <br />12:17:00 <br />11:55:00 <br />Initial Reading (RI): <br />0.00000 in. <br />0.00000 in. <br />0.00000 in. <br />0.00000 in. <br />Test End Time: <br />12:32:00 <br />12:10:00 <br />12:32:00 <br />12:10:00 <br />Final Reading (RF): <br />0.00000 in. <br />0.00190 in. <br />0.00070 in. <br />-0.00060 in. <br />Test Duration: <br />15 min <br />15 min <br />15 min <br />15 min <br />Change in Reading (RF -R,): <br />0.00000 in. <br />0.00190 in. <br />0.00070 in. <br />-0.00060 in. <br />Pass/Fail Threshold or Criteria: <br />+/-0.00200 <br />+/-0.00200 <br />+/-0.00200 <br />+/-0.00200 <br />Test Result: <br />Pass <br />Pass <br />Pass ' <br />Pass <br />Was sensor removed for testing? <br />G Yes r No r NA <br />ro Yes r Nor NA <br />ro Yes r Nor NA <br />ro Yes r Nor NA <br />Was sensor properly replaced and <br />verified functional after testing? <br />ro Yes r No r NA <br />ro Yes r Nor NA <br />ro Yes r Nor NA <br />ro Yes r Nor NA <br />CommentS - (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />1 If the entire depth of the UDC is not tested, specify how much was tested. If the answer to any of the questions indicated with an asterisk (*) is "NO" or "NA", the entire UDC must <br />be tested. <br />WO: 2316238 <br />R <br />