Laserfiche WebLink
1 <br />RECEIVED <br />0 <br />0 <br />SWRCB, January 2002 <br />' 0 7 Q4I of 1 <br />8. FILL RISER CONTAINMENT SUMP TESTING <br />Facility is Not Equipped With Fill Riser <br />Containment Sumps <br />Fill Riser Containment Sumps are Present, but were Not Tested <br />r <br />Test Method Developed By: r <br />Sump Manufacturer <br />PF, Industry Standard Professional Engineer <br />Other (Specify) <br />Test Method Used By: <br />Pressure <br />r— vacuum <br />F Hydrostatic <br />Other (Specify) <br />Test Equipment Used: VPLT <br />Equipment Resolution: 0.00001 in. <br />Contairine o sFtntaiixent <br />For <br />Fill Canta3nnenF31 <br />, <br />��... <br />Tank TI: R.L.- <br />Tank'- I' -1 <br />Tank, °l 3; Diesel <br />Sump Diameter: <br />48.00 in. <br />48.00 in. <br />48.00 in. <br />in. <br />Sump Depth: <br />62.00 in. <br />62.00 in. <br />62.00 in. <br />in. <br />Height from Tank Top to Top of <br />0.00 <br />0.00 <br />0.00 <br />Highest Piping Penetration: <br />Height from Tank Top to Lowest <br />2200 <br />22.00 <br />22.00 <br />Electrical Penetration: <br />Condition of sump prior to testing: <br />good <br />good <br />good <br />Portion of Sump Tested <br />24 <br />24 <br />24 <br />Sump Material <br />Fiberglass <br />Fiberglass <br />Fiberglass <br />Wait time between applying <br />pressure/vacuum/water and starting <br />5 min <br />5 min <br />5 min <br />min <br />test <br />Test Start Time: <br />10:26:00 <br />10:26:00 <br />09:40:00 <br />Initial Reading (Rt): <br />0.00000 in. <br />0.00000 in. <br />0.00000 in. <br />Test End Time: <br />10:56:00 <br />10:56:00 <br />10:10:00 <br />Final Reading (RF): <br />-0.00160 in. <br />-0.00150 in. <br />-0.00080 in. <br />Test Duration: <br />30 min <br />30 min <br />30 min <br />Change in Reading (RF -Rt): <br />-0.00160 in. <br />-0.00150 in. <br />-0.00080 in. <br />Pass/Fail Threshold or Criteria: <br />+/-0.00200 <br />+/-0.00200 <br />+/-0.00200 <br />+/- <br />Test Result~ <br />Pass <br />Pass. <br />Past <br />Is there a sensor in the pump? <br />r* Yes r No <br />0 Yes r No <br />r Yes C No <br />r Yes r No <br />Does the sensor alarm when either <br />re Yes r"" Nor NA <br />ro Yes f? Nor NA <br />C. Yes r Nor NA <br />r Yes r No C NA <br />product or water is detected? <br />Was sensor removed for testing? <br />C Yes r Nor NA <br />Cw Yes r Nor NA <br />rp Yes f Nor NA <br />r Yes r Nor NA <br />Was sensor properly replaced and <br />ro Yes r~ No NA r <br />ro Yes C No NA C <br />ro Yes r No NA r <br />r Yes C No NA r <br />verified functional after testin ? <br />Comments - (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />WO: 2316238 <br />