My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2002-2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LOWER SACRAMENTO
>
8660
>
2300 - Underground Storage Tank Program
>
PR0231161
>
COMPLIANCE INFO_2002-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/13/2023 2:51:09 PM
Creation date
6/3/2020 9:45:40 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2002-2015
RECORD_ID
PR0231161
PE
2361
FACILITY_ID
FA0003726
FACILITY_NAME
fast and easy mart #103
STREET_NUMBER
8660
STREET_NAME
LOWER SACRAMENTO
STREET_TYPE
RD
City
STOCKTON
Zip
95210
APN
079-170-390-000
CURRENT_STATUS
01
SITE_LOCATION
8660 LOWER SACRAMENTO RD
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231161_8660 LOWER SACRAMENTO_2002-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
484
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Oct 21 12 04:45p Lower Sacramento Chevron 2099540582 p.3 <br /> SWW`13,January 2002 Page__ <br /> of - <br /> 4. TANK ANNULAR TESTING <br /> Test Method Developed By: x Tank Manufactrnw Cl Industry Standard F,Professional Engineer <br /> I Other(Specify) <br /> Test Method Used: D Pressure x Vacuum El Hydrostatic <br /> Q Other(Sped) <br /> rest Equipment Used:Dwyer Manometer Equipment Resolution: 2% <br /> ............ <br /> ........... <br /> . ........ T IM. <br /> Tank# 3 <br /> Ta n k H I Tank ff 2 Tank#i <br /> 'z, <br /> is,rani:Exempt From Testing?' 5"]Yes xNo 11 Yes x No 0 Yes x No <br /> Tank Capacity: 10,000 10,000 10,000 <br /> '1't�nit.Material: Fiberglass Fibeqylass Fiberglass <br /> Tank Manu Iacturcr: Xeres Xeres Xeres <br /> Product Stored: Super Plus Regular <br /> Wait time bctween applying <br /> pressurelvactsurnAvater and 30 min 30 min 30 min 30 min <br /> 54Irting test: <br /> L - <br /> Test Stan Time: 9:15 9.,30 10:45 <br /> Initial Reading(Rj): 6.82 6.85 6.88 <br /> Test FTid Time: 10:15 10:30 11:45 <br /> Final Reading{RF): 6.76 6.63 6.68 <br /> 71 hour I hour I hour <br /> I*aSt Duration: I hour <br /> Changc in Reading(RF-RI): .06 '22 20 <br /> - <br /> 1';:,.;,s/Fail Threshold or Criteria: i Nc>less than I" No less than I" No less than I" No less tha r; I" <br /> Test Result: x Pass 0 Fail x Pass 0 Fail x Pass 0 Fail 0 Pass 0 Fail <br /> Was sensor removed for testing;? 'Ye's DNo GNA x Yes 0 No 13 NA xyes fNo (INA xYes <br /> lbws sensor properly replaced and <br /> :? x Yes D NA x Yes (] .9 No NA x Yes IJ No 0 NA xYes IN <br /> eri tied functional after ttstilio NA <br /> vd <br /> ('OMmeats—(Inchtde igLnzafion on repairs made prior h)le-Wing, and recommended fqflam-Lip or afled tests} <br /> ............ <br /> —----------- <br /> Secondary containment systems where the continuous monitoring automatically MODitOTS both the primary and Secondal-y <br /> containment,such as systems that are hydrostatically monitored or under constant vacuum,are exempt from periodic containment <br /> test:11g, {California Code of Regulations, Title 23,Section.2637(a)(6)) <br />
The URL can be used to link to this page
Your browser does not support the video tag.