My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2002-2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LOWER SACRAMENTO
>
8660
>
2300 - Underground Storage Tank Program
>
PR0231161
>
COMPLIANCE INFO_2002-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/13/2023 2:51:09 PM
Creation date
6/3/2020 9:45:40 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2002-2015
RECORD_ID
PR0231161
PE
2361
FACILITY_ID
FA0003726
FACILITY_NAME
fast and easy mart #103
STREET_NUMBER
8660
STREET_NAME
LOWER SACRAMENTO
STREET_TYPE
RD
City
STOCKTON
Zip
95210
APN
079-170-390-000
CURRENT_STATUS
01
SITE_LOCATION
8660 LOWER SACRAMENTO RD
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231161_8660 LOWER SACRAMENTO_2002-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
484
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
The following is an itemized list of underground storage tank violations that have not <br /> been addressed for LOWER SACRAMENTO CHEVRON* as of December 30, 2014. <br /> Open violations from October 16, 2014 inspection <br /> Violation#106 -Monitoring and response plans not current or approved by the EHD. <br /> The monitoring plan is not current and/or not approved by the EHD. The monitoring plan information for the tanks wit <br /> ID#"s TA0508375, TA0508376 and TA0508377 is not complete or is incorrect. <br /> The tank with ID#TA0508375 <br /> -Section for"Tank Monitoring is Performed using the following Methods" is incomplete. <br /> -Section for" Pipe Monitoring is Performed Using the following Methods" does not indicate if the line leak detector <br /> test is mechanical or electrical. <br /> -Section for" Under Dispenser Containment(UDC) Monitoring" is incomplete. <br /> -Section for" Periodic System Testing" is incorrect. <br /> -Section for" Recordkeeping" is incorrect. <br /> -Section for"Training"does not indicate the training done at the facility. <br /> The tank with ID#TA0508376 <br /> -Section for"Tank Monitoring is Performed using the following Methods" is incomplete. <br /> -Section for" Pipe Monitoring is Performed Using the following Methods" does not indicate if the line leak detector <br /> test is mechanical or electrical. <br /> -Section for" Under Dispenser Containment(UDC) Monitoring" is incomplete. <br /> -Section for" Periodic System Testing" is incorrect. <br /> -Section for"Training" is incorrect, operating manuals needs to be checked as yes. <br /> The tank with ID#TA0508377 <br /> -Section for"Tank Monitoring is Performed using the following Methods" is incomplete. <br /> -Section for" Pipe Monitoring is Performed Using the following Methods" is incomplete. <br /> -Section for" Under Dispenser Containment(UDC) Monitoring" is incomplete. <br /> The monitoring plan must be uploaded to the California Environmental Reporting System (CERS). Immediately log <br /> into CERS, make the necessary changes, and submit for review by the EHD. The response plan is not current and/( <br /> not approved by the EHD. The response plan must be uploaded to the California Environmental Reporting System <br /> (CERS). Immediately log into CERS, upload the completed form, and submit for review by the EHD. Ensure a copy <br /> is available for inspection at any time. This is a minor violation. <br /> Violation#107-Plot plan/site map not submitted or failed to completely show where monitoring is <br /> performed. <br /> An accurate UST Monitoring Site Plan was not submitted. A site plan must be submitted identifying the locations <br /> where monitoring will be performed. Immediately log into the California Environmental Reporting System (CERS) at <br /> http://cers.calepa.ca.gov/and upload a copy of the UST Monitoring Site Plan. This is a minor violation. <br /> Violation#201 -Failed to maintain alarm logs and/or records of follow up actions. <br /> Maintenance and monitoring records for the last three years were not found on site. A D.O report states that a <br /> technician was notified for a December 17, 2013 Gross Line Fail Alarm, but there was no invoice or other paperwork <br /> indicating how the alarm was addressed. These records shall be maintained on site for at least three years. <br /> Monitoring records include: (1)date and time of all monitoring or sampling; (2) monitoring equipment calibration and <br /> maintenance records; (3) results of any visual observations; (4) results of sample analysis performed a lab or in the <br /> field; (5) logs of all readings of gauges or other monitoring equipment, ground water elevations, or other test results; <br /> results of inventory readings and reconciliations. Immediately locate and maintain all maintenance and monitoring <br /> records for the last three years on site and submit copies to the EHD. This is a repeat violation, Class II. <br /> Violation#204-Current monitoring plan approved by the EHD not found on site. <br /> An approved copy of the monitoring plans were not available for inspection. A copy of these plans shall be accessibl <br /> on site at all times. Immediately locate and retain a copy on site. This is a minor violation. <br /> Page 2 of 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.