COMPLIANCE INFO_2012-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MARCH
>
2701
>
2300 - Underground Storage Tank Program
>
PR0231176
>
COMPLIANCE INFO_2012-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/7/2023 4:14:10 PM
Creation date
6/3/2020 9:46:10 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2018
RECORD_ID
PR0231176
PE
2361
FACILITY_ID
FA0003798
FACILITY_NAME
MARCH LANE 76*
STREET_NUMBER
2701
Direction
W
STREET_NAME
MARCH
STREET_TYPE
LN
City
STOCKTON
Zip
95219
APN
11619007
CURRENT_STATUS
01
SITE_LOCATION
2701 W MARCH LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231176_2701 W MARCH_2012-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
356
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I. PIPINGSUMT TESTING <br /> Test Method Developed y: 0 Sump Manufacturer 0 Industry Standard D Professional Engineer <br /> Other(Specify) <br /> Test Method Used: D Pressure O Vacuum 0 Hydrostatic <br /> D Other(Spec6) <br /> Tcst Equi men'Used:I con Sump Tester Equipment Resolution: +!-0.00211 <br /> STPSump# Su p# STPSump# STP S mp# <br /> Sump Diameter: ®� <br /> Sump Depth: a <br /> I—Sump Material: <br /> Height from Tank Top to Top of <br /> Highest Piping ene tion: ve <br /> Height from'Tank Top to Lowest <br /> Electrical Penetration: ®' <br /> Condition of sump prior to testing.: <br /> Portion of Sump Tested' <br /> Does turbine shut down when <br /> sump sensor detectsliquid(both p Yes 0 Na HNA O Yes D No DNA O Yes No O NA Q Yes D No DNA <br /> roduct and water)?* <br /> Turbine shutdown response time <br /> Is system programmed for fail-safe D Yes ONO IENA DYesDNo DNA Yes No O NA OYes ONO DNA <br /> shutdown?* <br /> Was fail-safe verified to be <br /> o ianal?' O Yes D No ®NA O Yes O No DNA O Yes O No O NA ❑Yes O No DNA <br /> erat <br /> Wait time between applying <br /> pressure/vacuum/water and starting 30 minutes 30 minutes 30 minutes 30 minutes <br /> test: <br /> Test Start Time: <br /> Initial Reading W: <br /> Test End Time: �, t <br /> Final Reading(RF). <br /> Test Duration: 1 <br /> Change in Reading(RF-Ri): <br /> Pass/Fail Threshold or Criteria: +/-0.002" +J-0.002" +/-0.002" +1-0.002" <br /> TestResult: M Pass ❑Fail ❑ Pass ❑Fail ❑ Pass ❑Fail p Pass ❑Fail <br /> Was sensor removed for testing? Yes O No NA ®Yes®No NA Yes No❑NA ❑Yes O No Q A <br /> Was sensor properly replaced d Yes D Ada NA Yes No DNA O Yes O No O A ❑Yes No ❑ A <br /> verified functional after testing? <br /> Comments—(include infr�rrtaatian on repairs made prior to testing, and recd endedfb11aw-up for failed tests) <br /> 'If the entire depth of the sump is not tested,specify how much was tested. If the answer to any of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire sump must be tested. (See SWRCB LG-160) <br />