My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MARCH
>
2701
>
2300 - Underground Storage Tank Program
>
PR0231176
>
COMPLIANCE INFO_2012-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/7/2023 4:14:10 PM
Creation date
6/3/2020 9:46:10 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2018
RECORD_ID
PR0231176
PE
2361
FACILITY_ID
FA0003798
FACILITY_NAME
MARCH LANE 76*
STREET_NUMBER
2701
Direction
W
STREET_NAME
MARCH
STREET_TYPE
LN
City
STOCKTON
Zip
95219
APN
11619007
CURRENT_STATUS
01
SITE_LOCATION
2701 W MARCH LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231176_2701 W MARCH_2012-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
356
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Underground Storage Tank Program Inspection Report <br />Facility Name: <br />MARCH LANE 76* <br />Facility Address: <br />2701 W MARCH LN, STOCKTON, CA 95219 <br />Facility Phone: <br />(209)473-7337 <br />Program: <br />2361 -UST FACILITY <br />Inspection Type: <br />ROUTINE INSPECTION -Operating Permit <br />Date: <br />December 19,2018 <br />San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California95205-6232 <br />Telephone:(209)468-3420 Fax :(209)468-3433 Web:www.sjgov.org/ehd <br />CERS ID: <br />10181433 <br />Inspection Contact: <br />Darren Eppler <br /> Consent For:Consent Given By: <br />Darren Eppler, Manager <br />Title: <br />Manager <br />Phone: <br />(209)473-7337 <br />Inspection Photos Samples <br />Service Technician Manufacturer's Training: <br /> Veeder-Root, 04/12/19; VMI, 11/01/20; SB, 01/09/19 <br />Service Technician Onsite: <br />Kris Bell <br />Exp.Date: <br />07/22/2020 <br /> Designated Operator: <br />Kris Bell <br />Exp.Date: <br />11/17/2019 <br />R =Repeat violation COS =Corrected on site during inspectionV=Violation <br />CCR =California Code of Regulations HSC =Health and Safety Code CFR =Code of Federal Regulations <br />File Review <br />101 □ V □ R □ COSFailed to obtain a permit to operate from the EHD including but not limited to unpaid permit feesHSC 25284 <br />102 □ V □ R □ COSNo written agreement between tank owner and tank operator to monitor the tank systemHSC 25284(a)(3)(A)/(B) <br />103 □ V □ R □ COSFailure to submit and maintain complete and current financial responsibility documentsHSC 25292.2, 25299.30 <br />104 ■ V □ R ■ COSUST operating permit application for facility and tank information not submitted or currentCCR 2711 <br />105 ■ V □ R ■ COSFailed to have an approved UST monitoring planCCR 2632(d)(1), <br />2634(d) <br />106 ■ V □ R ■ COSFailed to have an approved UST response planCCR 2632(d)(2), <br />2634(e) <br />107 □ V □ R □ COSPlot plan/site map not submitted or failed to completely show where monitoring is performedCCR 2632(d)(1)(C) <br />108 □ V □ R □ COSFailed to notify the EHD 48 hours prior to conducting testingCCR 2637, 2638(e), <br />2643(g) <br />109 □ V □ R □ COSFailed to test secondary containment, or failed to maintain test records for 36 monthsCCR 2637(a-d), 2712 <br />110 □ V □ R □ COSFailed to submit "Secondary Containment Testing Report Form" within 30 days after the testCCR 2637(e), 2637(f) <br />111 □ V □ R □ COSFailed to test monitoring and leak detection equipment annuallyCCR 2638(a) & (b), <br />2641(j) <br />112 □ V □ R □ COSFailure to maintain UST records to enable the UPA to determine whether the UST is in complianceHSC 25293 <br />113 □ V □ R □ COSFailure to submit "Monitoring System Certification Form" within 30 days of completion of the testCCR 2638(c), 2638(d) <br />114 □ V □ R □ COSNo 0.1 gph annual line integrity test for pressurized piping, or within 30 days after repairCCR 2636(f)(3), 2643(c) <br />(3) <br />115 □ V □ R □ COS"Designated Underground Storage Tank Operator Identification Form" not submitted within 30 daysCCR 2715(a)(1)(B), <br />2715(a)(3) <br />116 □ V □ R □ COSDesignated operator, service tech or installer did not possess current ICC certificationCCR 2715 <br />117 □ V □ R □ COSFailure to comply with tank lining, recordkeeping, and inspection requirementsCCR 2663, 2712(b)(6) <br />118 ■ V □ R ■ COSFailure to submit the "Underground Storage Tank Statement of Understanding and Compliance Form"CCR 2715(a)(1)(A), <br />2715(a)(2) <br />119 □ V □ R □ COSDocuments were falsified or misrepresentedHSC 25299(a)(8), <br />25299(b)(7) <br />120 □ V □ R □ COSFailed to submit UST Certification of Installation/ModificationCCR 2635(d) <br />121 □ V □ R □ COSFailed to submit a written response within 30 days of receiving an inspection reportCCR 2712(f) <br />122 □ V □ R □ COSFailure to submit and/or maintain documentation regarding compatibility for UST system componentsCCR 2631, 2640.1, <br />2665, 2711 <br />Page 1 of 6 <br />FA0003798 PR0231176 SC001 12/19/2018 <br />EHD 23-01 Rev. 09/22/16 Underground Storage Tank Program OIR
The URL can be used to link to this page
Your browser does not support the video tag.