Laserfiche WebLink
Underground Storage Tank Program Inspection Report <br />Date: <br />December 19,2018 <br />Facility Address: <br />2701 W MARCH LN, STOCKTON <br />Facility Name: <br />MARCH LANE 76* <br />San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California95205-6232 <br />Telephone:(209)468-3420 Fax :(209)468-3433 Web:www.sjgov.org/ehd <br />File Review <br />123 □ V □ R □ COSFailure to submit the "Spill Container Testing Report Form" within 30 days after the testCCR 2637.1(d), <br />2637.1(e) <br />124 □ V □ R □ COS"Overfill Prevention Equipment Inspection Report Form" not submitted within 30 days of inspectionCCR 2637.2(d&e), <br />2665(a&b) <br />On Site Records <br />201 □ V □ R □ COSFailure to maintain monitoring, maintenance, and follow up action recordsCCR 2712(b) <br />202 □ V □ R □ COSFailure to maintain the "Facility Employee Training Certificate" on-site (after October 1, 2018)CCR 2715(c)(3), <br />2715(c)(4) <br />203 □ V □ R □ COSFailure to maintain records of repairs, lining, and upgrades on site, for the life of the USTCCR 2712(b) <br />204 □ V □ R □ COSCurrent monitoring plan approved by the EHD not found on siteCCR 2712(i) <br />205 □ V □ R □ COSFailure to submit a current UST Response Plan and have it available onsiteCCR 2712(i), 2634(e) <br />206 □ V □ R □ COSFailure to comply with UST operating permit conditionsCCR 2712 <br />207 □ V □ R □ COSFailed to record unauthorized release from primary containmentHSC 25294 <br />208 □ V □ R □ COSFailed to notify the EHD of a reportable unauthorized release and/or prepare a reportCCR 2650(e), 2652 <br />209 ■ V □ R □ COSFailure to conduct the designated UST operator visual inspection at least once every 30 daysCCR 2716(a-e) <br />210 □ V □ R □ COSDO monthly reports not maintained on site for 12 months or for 36 months (after October 1, 2018)CCR 2716(f) <br />211 □ V □ R □ COSNo employee present that were trained in the operation and maintenance of the UST system by a DOCCR 2715(c)(2) <br />212 □ V □ R □ COSUnstaffed facility failed to have or implement a training program approved by the EHDCCR 2715(f)(2) <br />213 □ V □ R □ COSUnburied fuel piping at marinas not visually inspected at least daily or log not keptHSC 25281.5(b)(2) <br />214 □ V □ R □ COSUnburied emergency generator fuel piping not visually inspected at least monthly or log keptHSC 25281.5(b)(3) <br />215 □ V □ R □ COSFailure to retain a copy of the permit to operate at the facilityCCR 2712(i) <br />UST System Observations <br />301 □ V □ R □ COSUST system is not operated to prevent unauthorized release, including spills and overfillsHSC 25292.1(a) <br />302 □ V □ R □ COSUST system incapable of detecting leak from primary into secondary containment (pre-Jul 2003)HSC 25291(b) <br />303 □ V □ R □ COSMonitoring system not maintained to detect entry into secondary containment (Jul 2003-Jun 2004)HSC 25290.2(d) <br />304 □ V □ R □ COSMonitoring system not maintained to detect entry into secondary containment (after Jul 2004)HSC 25290.1(d) <br />305 □ V □ R □ COSVPH monitoring of the interstitial spaces of the UST system is not maintainedHSC 25290.1(e) <br />306 □ V □ R □ COSMonitoring equipment is not installed or maintained to detect a leak at the earliest opportunityCCR 2630(d) <br />307 □ V □ R □ COSMonitoring system of the interstitial space of a double walled system not maintainedCCR 2631(g), 2632(c) <br />308 □ V □ R □ COSFailed to maintain a continuous monitoring system that activates an audible and visual alarmCCR 2636(f) <br />309 ■ V □ R ■ COSMonitoring in sump / UDC failed to activate an audible and visual alarm or stop the flow productCCR 2636(f)(1) <br />310 □ V □ R □ COSPiping is not fail-safe outside UDCs or fails to stop flow of product at dispenser inside UDCsCCR 2636(f)(4) <br />311 □ V □ R □ COSFailed to properly program, calibrate, operate, or maintain leak detection equipmentCCR 2638(a), 2641(j) <br />312 □ V □ R □ COSFailed to affix a tag sticker on monitoring equipment certified, repaired, or replacedCCR 2638(f), 2641(i) <br />313 □ V □ R □ COSFailure to construct, operate, and maintain primary containment as product-tightHSC 25290.1, 25290.2, <br />25291 <br />314 □ V □ R □ COSFailed to have secondary containment or secondary containment not tightHSC 25290.1, 25290.2, <br />25291 <br />Page 2 of 6 <br />FA0003798 PR0231176 SC001 12/19/2018 <br />EHD 23-01 Rev. 09/22/16 Underground Storage Tank Program OIR