My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2003-2008
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
4511
>
2300 - Underground Storage Tank Program
>
PR0231216
>
COMPLIANCE INFO_2003-2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/4/2023 2:32:22 PM
Creation date
6/3/2020 9:46:14 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2003-2008
RECORD_ID
PR0231216
PE
2361
FACILITY_ID
FA0002480
FACILITY_NAME
SHOP N GO 3
STREET_NUMBER
4511
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
11023011
CURRENT_STATUS
01
SITE_LOCATION
4511 PACIFIC AVE
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231216_4511 PACIFIC_2003-2008.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
347
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 Page 5 of <br /> 7. UNDER-DISPENSER CONTAINMENT QTCj TESTING <br /> Test Method Developed By: ❑UDC Manufacturer ❑Industry Standard Professional Engineer <br /> ❑Other(Spec6) <br /> Test Method Used: ❑Pressure ❑Vacuum ydrostatic <br /> ❑Other(Spec6) <br /> Test Equipment Used:C4 jaWe 1 e Equipment Resolution: ,D,c5- <br /> UDC# L L UDC# 3Z- UDC# S"X A- I VDC# <br /> UDC Manufacturer: ��iia�wei- 1-p-Eee Cad <br /> UDC Material: w ( o l d[ <br /> UDC.D the "`Z ? 2.`� 2`7 z 'r <br /> Height from UDC Bottom to Top <br /> of Hi est Pi in Penetration: <br /> Height from UDC Bottom to ! ► 1 t ! ! <br /> Lowest Electrical Penetration: <br /> Condition of UDC prior to <br /> Portion of UDC Tested wa l K l e,.e,L 11 wairLeyet_W? t d r <br /> Does turbine shut down when <br /> UDC sensor detects liquid(both es ❑No ❑NA es ❑No ❑NA es ❑No ❑NA ❑Yes o ❑NA <br /> ,product and water?° <br /> Turbine shutdown re onse time. ce <br /> Is system programmed for fail- <br /> safe shutdown?' Yes ❑No ❑NA es ❑No ❑NA es ❑No ❑NA ❑Yes A4o ❑NA <br /> Was fail-safe verified to be <br /> operational?* es 0 No ❑NA ❑No ❑NA Yes ❑No ❑NA ❑Yes o ❑NA <br /> Wait'time between a ing <br /> pressure/vacuum/ ater d <br /> startin test AD r"1 i W e , „r <br /> h44ktll to r. <br /> Test Start Time: 1 Z: --t2,130 t! D <br /> Initial Readin 'ry + 6V-04 Gtr F v5A-C 4. <br /> Test End Time: 11, 105 d v W, to <br /> Final Reading Fc r +_ C.� <br /> Test L?uration: D!�[.H.u+� > y�y 38 rel i <br /> Chane in Reading(RF-F.1): Na P✓o IV o <br /> Pass/Fail Threshold or Criteria: Oct �dS t3D S" <br /> ;_'Te�t� Bits; s t1.�'srl . . f��nY� :: ;:Pass_ :❑F��`:. ,° .. : n....." . <br /> Was sensor removed for testing? es ❑No ❑NA es ❑No ❑NA es ❑No ❑NA ❑ es ❑No 0 N <br /> Was sensor properly replaced and verified functional after testin ? es ❑No ❑NA Ares ❑No ❑NA , Yes ❑No ❑NA Yes ❑No 0 N <br /> Comments—(include information on repairs made prior to testing, and recommended follow up for failed tests) <br /> 'If the entire depth of the UDC is not tested,specify how much was tested. If the answer to M of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire UDC must be tested. (See SWRCB LG-160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.