My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2003-2008
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
4511
>
2300 - Underground Storage Tank Program
>
PR0231216
>
COMPLIANCE INFO_2003-2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/4/2023 2:32:22 PM
Creation date
6/3/2020 9:46:14 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2003-2008
RECORD_ID
PR0231216
PE
2361
FACILITY_ID
FA0002480
FACILITY_NAME
SHOP N GO 3
STREET_NUMBER
4511
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
11023011
CURRENT_STATUS
01
SITE_LOCATION
4511 PACIFIC AVE
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231216_4511 PACIFIC_2003-2008.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
347
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
07/22/2003 13:45 2094683433 FIFTH FLOOD PAUL 021 <br /> I <br /> Underground Storage Tank Monitoring ragc 2 <br /> 0 C. Pipeline Monitoring <br /> toring is performed using the following methods: (Check all which apply) <br /> Lute <br /> electronic monitoring of piping swnp(s)/trench and other secondary containment)o points. <br /> Leak Sensor Manufacturer: <br /> --_ Model No.: �r5 P ,w5; <br /> Will a piping leak alarm trigger automatic shutdown of the pump(i.e. turbine)?' Yes; Ej No. <br /> Wijl failure/disconnection of monitoring systern trigger automatic shutdown of pump? es-' Ej No. <br /> Mechanical line leak detector. (MLLD)that routinely performs 3.0 g,p.h. leak tests and restricts or shuts off <br /> product flow when a leak is detected <br /> MLLD Manufacturer: �� I Model No.: F X I V <br /> ❑Electronic line leak detecto—r(ELLD)thatroutinelyperforms 3.0 g.p.h. leak tests. <br /> ELLD Manufactm-ur: Model No.: <br /> Pro £d line tightness tests: ❑Minimurn Monthly 0.2 g.p.h.; E]Minimum Annual_01--g–p.h. <br /> Will ELLD detection of a piping leak trigger automatic shutdown of the pump? El Yes;Q No. <br /> Will failure or disconnection of the ELLD trigger automatic shutdown of the piunp? Clyes; nNo. <br /> E]Line tightness testing conducted:F] Annually;E Every 3 years;E3 Other(specify): <br /> E]No product or remote-fill piping is connected to the UST(s). <br /> ❑ Piping is suction Piping meeting all requirelnerits for exemption from monitoring. [See 23 CCR§2636(a)(3)] <br /> ❑ Other(specify): <br /> ID. Dispenser Leak Detection: (Cheek all which apply) <br /> []No dispensers in system. <br /> Ll float and chain assembly in under-dispenser containment trips shear-valve in case of leak. <br /> Pr( <br /> Assembly Manufactmer: Model No.: <br /> Continuous electronic monitoTiqg of under-dispenser contairtment. <br /> Leak Sensor Manufacturer- Model No.: P® U L <br /> Will a leak trigger audible and visual alarms? es, L]-No. <br /> Will a leak alarm trigger automatic shutdown of the pump? No. <br /> Will failureldi&connection of monitoring systern bigger automatic shutdown of pump? ryy5_1,❑No. <br /> 0 Dispenser housings are opened and fittings inside are visually inspected daily for leaks (required if under- <br /> dispenser containment is not installed). <br /> El Other(speci <br /> E. Monitoring Locations <br /> Included with this monitoring plan is a Site Plan which shows the general tank and piping layouts and. tho <br /> locatiQlis where Monitoring is peribimed(i-e. locations of sqnsors,J'pc <br /> I T44 detectou, QQ11trol panels,em.), <br /> &'N-022A.2/6 NOW.971DZIP? <br />
The URL can be used to link to this page
Your browser does not support the video tag.