My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1999-2009
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
1301
>
2300 - Underground Storage Tank Program
>
PR0231342
>
COMPLIANCE INFO_1999-2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/4/2021 3:26:07 PM
Creation date
6/3/2020 9:46:53 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1999-2009
RECORD_ID
PR0231342
PE
2361
FACILITY_ID
FA0000392
FACILITY_NAME
FLAMES LIQUOR
STREET_NUMBER
1301
Direction
W
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95242
APN
03104030
CURRENT_STATUS
01
SITE_LOCATION
1301 W KETTLEMAN LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231342_1301 W KETTLEMAN_1999-2009.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
391
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Jul 08 09 11:34a Elite Iv Contractors Inc 2094616342 P.8 <br />Vaporless 99 LD -2000 Addendum <br />6.0 Test Results and Limitations <br />The performance parameters for the 99 LD -2000 are summarized in Table 3. <br />Probabili of Dete.ption P <br />The 99 LD -2000 was correct in its determination of a leak for all of the leak- tests. The estimated <br />PO of a 3 gal/h leak is 100% with an upper confidence limit of 61 to 100%. <br />Probabilily_2�f'r,al.,qe&1,,tmi LPFA). <br />- <br />The 99 LD -2000 was correct in its determination of a tight pipeline for all of the tight tests. The <br />estimated PvAis 0% with a lower confidence limit of 0 to 39%. <br />Time to Conduct a Test <br />All of the tests, were completed in under one minute with one exception. One of the tests required <br />20 minutes to complete due to a temperature differential extreme that was present during the test <br />(See Table 1). <br />Maximum Line Size <br />The EPA protocol allows pipeline leak detection methods to be used on pipelines with up to <br />twice the volume of that used in the evaluation. If the EPA protocol is used to calculate the <br />performance parameters, the 99 LD -2000 can be used on rigid pipelines up to 170 gallons and <br />flexible pipelines Lip to 39.5 gallons. <br />Page 7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.