Bonding primary Using heating blankets <br /> systems `Cont.) Ameron heating blankets provide an efficient means for curing adhesive-bonded joints. <br /> Two sizes are needed for installing <br /> Dualoy 30001 systems.Refer to Chem Cure Pak quantities and heating <br /> following table when ordering. blanket sizes <br /> The heatingblanket reaches a Nominal Chem Heating <br /> Pipe Size Cure Pak Blanket <br /> maximum temperature of 250°F (in (mm) Units per Carton Size <br /> (120°C),which will cure Ameron 2 50 30 1 <br /> PSX•20 adhesive in approximately 3 80 30 1 <br /> 30 to 40 minutes.Detailed instructions 4 100 20 1 <br /> are included with the blanket.Observe 6 150 20 II <br /> the following points: <br /> • Use one heating blanket per <br /> bond:sleeve couplings in 3-inch sizes and larger will require two blankets. <br /> However,a single blanket is sufficient for curing both bonds in a 2-inch sleeve <br /> coupling. <br /> • Tie the blanket in place with nonconducting ties. <br /> • Before connecting to a power source,inspect the blanket and cord for loose wire <br /> connections and bare wires. <br /> • Do not plug the cord into a power source when standing in water or on a wet <br /> surface. <br /> • Check that the heating blanket has the correct AC voltage rating for your locality. <br /> Do not use direct current. <br /> • Mark the starting and disconnect time on the pipe with a grease pencil so that you <br /> will have a record of cure for each joint. <br /> • Verify that the blanket actually heats up after being plugged in. <br /> Blanket <br /> i <br /> Fitting <br /> Fig.7-2.Place the thermostat end <br /> of the blanket against the joint <br /> with thermostat facing out.Wrap <br /> the rest of the blanket around the <br /> joint so that the overlap covers the <br /> thermostat. 0 <br /> Thermostat <br /> Fig.7-3.When itis windy or below Fiberglass insulation backed by 4 <br /> 50°F(10°C),close the pipe ends and aluminum foil <br /> insulate around the blanket.Overlap <br /> the blanket about 4 inches on each <br /> side and tie down the ends of the <br /> insulation. <br /> Connecting to non-Ameron fiberglass piping <br /> Connect Dualoy 3000/1-fiberglass piping and non-Ameron UL-listed fiberglass piping by <br /> means of threaded adapters.Do not adhesive bond Ameron piping to that of another <br /> manufacturer.Bond the appropriate adapter from each manufacturer to the manufac- <br /> turer's pipe using that manufacturer's adhesive.Complete the threaded connection <br /> using thread sealant,not pipe adhesive.By following this procedure you can use <br /> Dualoy 30001 piping to extend an existing line that employs the pipe from another <br /> manufacturer without voiding the UL listing of either system. <br /> 11 <br />