My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009-2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LOCKEFORD
>
1225
>
2300 - Underground Storage Tank Program
>
PR0231350
>
COMPLIANCE INFO_2009-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/13/2023 1:38:11 PM
Creation date
6/3/2020 9:47:43 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2015
RECORD_ID
PR0231350
PE
2361
FACILITY_ID
FA0003690
FACILITY_NAME
LODI FOOD & LIQUOR*
STREET_NUMBER
1225
Direction
W
STREET_NAME
LOCKEFORD
STREET_TYPE
ST
City
LODI
Zip
95240
APN
03710002
CURRENT_STATUS
01
SITE_LOCATION
1225 W LOCKEFORD ST
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231350_1225 W LOCKEFORD_2009-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
481
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 <br /> SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.s*gov.org/ehd <br /> UNDERGROUND STORAGE TANK(UST) PROGRAM INSPECTION REPORT CONTINUED <br /> NameFacilit: Lodi Food & Liquor address: 1225 W. Lockeford St. Lodi, CA Date: <br /> Nov 20, 2013 <br /> VIOLATIONS <br /> # C1 C2 M Code Section HSC=CA Health and Safety Code;CFR=Code of Federal Regulations <br /> C1=Class 1 violation;C2=Class 2 violation;M=Minor violation <br /> con#tn <br /> 702 CCR 2643(e) Biennial tightness test of gravity piping not performed(pre-January 1,1984) (Mi) <br /> 703 CCR 2643(d) Triennial line test for conventional suction piping not performed(pre-January 1,1984) (M1) <br /> .� Violations <br /> "999 Other: See attached"Continuation—Official Inspection Report"for violations)not listed above. <br /> SUMMARY OF VIOLATIONS <br /> CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Revised inspection report 11-22-13. Violations 105 and 106 have been rescinded. The required <br /> information has already been entered into the California Electronic Reporting System. This report <br /> supersedes the initial report provided on 11-20-13. <br /> On site to conduct the routine inspection and witness the annual monitoring system certification testing. <br /> 202. Current approved copies of the monitoring and response plans were not found on site. The <br /> monitoring and response plans must be current and approved by the EHD. A copy of the approved <br /> monitoring plan and response plan were provided to the site operator during the inspection. <br /> 201. Test records for the most recent monitoring system certification and secondary containment testing <br /> were not on site. Maintenance records and a facility alarm log for the 8-25-13, 7-16-13, and 5-15-13 <br /> diesel sump sensor alarms were not found on site. These records shall be kept on site for at least 3 <br /> years. Immediately locate and maintain the test records, maintenance records, and a facility alarm log <br /> on site and submit copies to the EHD by December 20, 2013. <br /> 204. The designated operator failed to document all the alarms from the attached alarm history on the <br /> September 2013, July 2013, and May 2013 designated operator monthly inspection reports and failed to <br /> check that they were responded to appropriately. The missing alarms include: 8-25-13, 7-16-13, and <br /> 5-15-13 diesel sump alarms. During the monthly inspection, the designated operator shall review the <br /> alarm history for the previous month, check that each alarm was documented and responded to <br /> appropriately, and attach a copy of the alarm history with documentation taken in response to any <br /> alarms to the monthly report. Ensure that designated operators performing monthly inspections at this <br /> facility are including all of the required information on the reports. <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Inspector: Received By: ' / Title: <br /> G�/�. <br /> EHD 23-02 Rev 04/19/12 Page 3 UST INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.