My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009-2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LOCKEFORD
>
1225
>
2300 - Underground Storage Tank Program
>
PR0231350
>
COMPLIANCE INFO_2009-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/13/2023 1:38:11 PM
Creation date
6/3/2020 9:47:43 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2015
RECORD_ID
PR0231350
PE
2361
FACILITY_ID
FA0003690
FACILITY_NAME
LODI FOOD & LIQUOR*
STREET_NUMBER
1225
Direction
W
STREET_NAME
LOCKEFORD
STREET_TYPE
ST
City
LODI
Zip
95240
APN
03710002
CURRENT_STATUS
01
SITE_LOCATION
1225 W LOCKEFORD ST
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231350_1225 W LOCKEFORD_2009-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
481
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB, January 2002 Page � of <br />6. PIPING SUMP TESTING <br />Test Method Developed By: ❑ Sump Manufacturer X Industry Standard ❑ Professional Engineer <br />❑ Other (Specify) <br />Test Method Used: ❑ Pressure ❑ Vacuum X Hydrostatic <br />❑ Other (Spec) <br />Test Equipment Used: INCON TS STS <br />Equipment Resolution: 0 <br />Sump # 87 <br />Sump # DSL <br />Sump # 91 <br />Sump # <br />Sump Diameter: <br />36" <br />36" <br />36" <br />Sump Depth: <br />45" <br />46" <br />46" <br />Sump Material: <br />F/G <br />F/G <br />F/G <br />Height from Tank Top to Top of <br />Highest Piping Penetration: <br />2211 <br />26„ <br />24" <br />Height from Tank Top to Lowest <br />Electrical Penetration: <br />16" <br />16" <br />16" <br />Condition of sump prior to testing: <br />DRY <br />DRY <br />DRY <br />Portion of Sump Tested' <br />2" ABOVE <br />2" ABOVE <br />2" ABOVE <br />Does turbine shut down when <br />sump sensor detects liquid (both <br />product and water)? <br />_ Yes ;- No X NA <br />= Yes = No X NA <br />Yes No X NA <br />_ Yes No __ NA <br />Turbine shutdown response time <br />N/A <br />N/A <br />N/A <br />Is system programmed for fail-safe <br />shutdown?` <br />Yes --No X NA <br />- Yes - No X NA <br />- Yes -. No X NA <br />i - Yes = No - NA <br />Was fail-safe verified to be <br />operational?* <br />- Yes XNo X NA <br />- Yes XNo X NA <br />- Yes XNo X NA <br />_ Yes _: No - NA <br />� d <br />Wait time between applying <br />pressure/vacuum/water and starting <br />test: <br />5 MIN <br />5 MIN <br />5 MIN <br />Test Start Time: <br />12:33 <br />12:33 <br />12:33 <br />Initial Reading (Rj): <br />3.4975 <br />1.7915 <br />4.7527 <br />Test End Time: <br />12:48 <br />12:48 <br />12:48 <br />i <br />Final Reading (RF): <br />3.4792 <br />1.7902 <br />4.7528 <br />j <br />Test Duration: <br />15 MIN <br />15 MIN <br />15 MIN <br />Change in Reading (RF -RI): <br />.0003 <br />.0013 <br />.0001 <br />Pass/Fail Threshold or Criteria: <br />.002 <br />.002 <br />.002 <br />u <br />Test Result: <br />X Pass ❑ Fail <br />X Pass ❑ Fail <br />X Pass ❑ Fail <br />❑ Pass ❑ Fail !i <br />Was sensor removed for testing? <br />XYes = No - NA <br />XYes - No - <br />NA <br />XYes .- No -- <br />NA <br />_,_Yes - No =: NA <br />Was sensor properly replaced and <br />verified functional after testing? <br />XYes -' No ` NA <br />XYes - No - <br />NA <br />XYes - No _- <br />NA <br />-'Yes - No == NA <br />Comments — (include information on repairs made prior to testing and recommended follow-up for failed tests) <br />1 If the entire depth of the sump is not tested, specify how much was tested. If the answer to ay.of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire sump must be tested. (See SWRCB LG -160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.