My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009-2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LOCKEFORD
>
1225
>
2300 - Underground Storage Tank Program
>
PR0231350
>
COMPLIANCE INFO_2009-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/13/2023 1:38:11 PM
Creation date
6/3/2020 9:47:43 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2015
RECORD_ID
PR0231350
PE
2361
FACILITY_ID
FA0003690
FACILITY_NAME
LODI FOOD & LIQUOR*
STREET_NUMBER
1225
Direction
W
STREET_NAME
LOCKEFORD
STREET_TYPE
ST
City
LODI
Zip
95240
APN
03710002
CURRENT_STATUS
01
SITE_LOCATION
1225 W LOCKEFORD ST
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231350_1225 W LOCKEFORD_2009-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
481
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• SAN JOAQUIN COUNTY • <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />600 East Main Street, Stockton, California 95202-3029 <br />Telephone: (209) 468-3420 Fan: (209) 468-3433 Web: www.siciov.org/ehd/unitiii.htmi <br />CONTINUATION FORM <br />Page: 4 of 4 <br />OFFICIAL INSPECTION REPORT <br />Date: 11 /23/10 <br />Facility Address: Lodi Food & Liquor 1225 W. Lockeford St. Lodi, CA 95240 <br />Program: UST <br />SUMMARY OF VIOLATIONS <br />CLASS 1, CLASS 11, or MINOR -Notice to Comply) <br />23c. The designated operator failed to check and note the correct test dates for the Monitoring <br />Certification, Leak Detector, and Spill Bucket tests on the 11-30-09 designated operator monthly <br />inspection report. The 11-30-09 D.O. report listed the Monitoring Certification, Leak Detector, and Spill <br />Bucket tests as 12-4-08, but it should be listed as 11-18-08. During the monthly inspection, the <br />designated operator shall check that all required testing and maintenance for the UST system have been <br />completed and document the dates they were done. Ensure that designated operators performing <br />monthly inspections at this facility are including all of the required information on the reports. Repeat <br />Violation. <br />23c. The designated operator failed to verify that all employees have been trained during the May <br />through October 2010 monthly inspections. Employee Zulfiqar Khan was hired May 2010 per Jaspal <br />Koont and has not yet been trained by the D.O. During the first part of the inspection Zulfiqar Khan was <br />working by himself. Jaspal Koont is the only D.O. trained employee at this time. During the monthly <br />inspection, the designated operator shall verify that all facility employees have been trained. Ensure that <br />designated operators performing monthly inspections at this facility are including all of the required <br />information on the reports. Repeat Violation. <br />23d. The designated operator employee training for Zulfiqar Khan was not performed. The designated <br />operator shall train facility employees for which he or she is responsible in the proper operation and <br />maintenance of the UST system once every 12 months. The training shall include, but is not limited to: <br />1. Operation of the UST system in a manner consistent with the facility's best management practices <br />2. Employee's role with regard to monitoring equipment as specified in the facility's monitoring plan <br />3. Employee's role with regard to spills and overfills as specified in the facility's response plan <br />4. Name of the contact person(s) for emergencies and monitoring equipment alarms <br />Ensure that employees have been trained by the designated operator, maintain the list on site, and <br />submit a copy of the training records to the EHD by 12-23-10. <br />Complete and submit a copy of the Return to Compliance Certification form with a statement of how <br />each violation was corrected, including supporting documentation, by 12-23-10. <br />ALL EHD STAFF 71ME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE ($122). <br />THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br />EHD Ins r: <br />Received By: <br />�� <br />Title: <br />EHD 23-02-003 Rev 08/10/10 CONTINUATION FORM <br />
The URL can be used to link to this page
Your browser does not support the video tag.