My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009-2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LOCKEFORD
>
1225
>
2300 - Underground Storage Tank Program
>
PR0231350
>
COMPLIANCE INFO_2009-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/13/2023 1:38:11 PM
Creation date
6/3/2020 9:47:43 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2015
RECORD_ID
PR0231350
PE
2361
FACILITY_ID
FA0003690
FACILITY_NAME
LODI FOOD & LIQUOR*
STREET_NUMBER
1225
Direction
W
STREET_NAME
LOCKEFORD
STREET_TYPE
ST
City
LODI
Zip
95240
APN
03710002
CURRENT_STATUS
01
SITE_LOCATION
1225 W LOCKEFORD ST
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231350_1225 W LOCKEFORD_2009-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
481
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sigov.or /q ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> LODI FOOD & LIQUOR' 1225 W LOCKEFORD ST LODI November 18 2015 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS 1,CLASS 11,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 314 CCR 2631(a) Primary containment not tight(pre-Jul 2003). <br /> A small amount of diesel fuel was found in the#3/4 under dispenser containment sump and diesel turbine sump, <br /> indicating a leak in the primary containment system. Diesel fuel was observed to have leaked from the diesel fuel filter <br /> in dispenser#3/4. All primary containment for the UST system must be tight. Immediately have a properly licensed, <br /> trained, and certified contractor repair or replace the failed component under permit and inspection of the EHD. <br /> This is a minor violation. <br /> 321 CCR 2636(c)(1)All releases in secondary piping do not flow to a collection sump. <br /> The test boot of the diesel product line in the diesel turbine sump was not pulled back, the test boot band clamps <br /> were firmly affixed, and the schrader valve was not facing downwards. Any potential release from the primary <br /> containment into the secondary containment in the diesel piping does not flow into a collection sump. All secondary <br /> containment systems shall be sloped so that all releases will flow to a collection sump located at the low point of the <br /> underground piping. Immediately contact a properly licensed, trained, and certified contractor to ensure that any <br /> releases in the diesel piping flows into the diesel sump. <br /> This is a Class II violation. <br /> 323 CCR 2636(f)(2) Leak detector failed to detect a 3.0 gph leak at 10 psi. <br /> The 87 VMI line leak detector failed to detect a leak when tested. All line leak detectors shall be capable of detecting <br /> a 3-gallon per hour leak at 10 psi. The service technician adjusted the leak detector, retested it, and it passed. <br /> This is a repeat violation, Class II. <br /> 325 CCR 2635(b)Spill container failed to contain a minimum capacity of five gallons. <br /> The 87 direct-bury spill container failed when tested. All spill containers shall have a minimum capacity of five gallons <br /> and be capable of containing a spill or overfill until it is detected or cleaned up. Immediately discontinue deposition of <br /> petroleum into this tank until the component is repaired or replaced by a properly licensed, trained, and certified <br /> contractor under permit and inspection of the EHD. If the spill container can't be replaced immediately, there is a <br /> possibility that the 87 UST system may be red tagged to prevent fuel inputs. <br /> This is a repeat violation, Class II. <br /> Overall Inspection Comments: <br /> On site to conduct a routine inspection and witness the annual monitoring system certification testing. <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, by 12-18-15. <br /> Please be aware that as of January 1, 2014, facility operators are required to upload the following UST program <br /> documents into the California Environmental Reporting System (CERS): UST Monitoring Site Plan, UST <br /> Received by Inspector: Phone: Date: <br /> (initial): �' k JARIS VELOSO, Senior REHS 1 (209)468-3453 11/18/2015 <br /> Page 6 of 7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.