My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1997
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
TURNER
>
2420
>
2300 - Underground Storage Tank Program
>
PR0231382
>
COMPLIANCE INFO_1997
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/9/2020 8:56:06 PM
Creation date
6/3/2020 9:48:07 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1997
RECORD_ID
PR0231382
PE
2361
FACILITY_ID
FA0004139
FACILITY_NAME
Plaza liquor and Gas
STREET_NUMBER
2420
Direction
W
STREET_NAME
TURNER
STREET_TYPE
RD
City
LODI
Zip
95242
CURRENT_STATUS
01
SITE_LOCATION
2420 W TURNER RD
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231382_2420 W TURNER_1997.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
397
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 <br /> File MH19589 Page T1-1 of 2 Issued: 1-30-97 <br /> T E S T R E C 0 R D N O. 1 <br /> SAMPLES : <br /> Representative samples of the CP1502, 1-1/2 in. nonmetallic <br /> secondary containment piping system were submitted to UL for <br /> evaluation and test under UL 971 . The CP1502 incorporated the <br /> Listed PP1502 primary pipe and a <br /> polyethylene, thick jacket . The following tests were <br /> considered necessary. <br /> No testing was considered necessary on the PP1502 . Tests <br /> were completed previously under a separate project, 94NK23919, <br /> File MH16395 , Test Record No. 1 . <br /> The Union Carbide jacket was tested previously under <br /> File MH19589, Report dated December 9, 1996, Test Record No. 1 . <br /> The results relate to the items tested. <br /> LEAKAGE- TEST: <br /> METHOD <br /> The interstitial space of the CP1502 were subjected to a <br /> aerostatic pressure of 10 psig for 5 min. The samples were <br /> observed for evidence of leakage and damage. <br /> RESULTS <br /> There was no evidence of leakage or damage. <br /> . RESISTANCE TO CRUSHING TEST: <br /> METHOD <br /> Representative samples of the CP1502 were placed between two <br /> parallel plates measuring 6 by 6 in. The pipe was then flattened <br /> until the distance between the plates was 40 percent of the <br /> original outside diameter of the pipe. The pipe was then <br /> examined for splitting, cracking, or other damage . <br /> RESULTS <br /> There was no evidence of splitting, cracking, breaking or <br /> other damage . <br /> LMD/TAS :nsc <br /> NKDLS <br />
The URL can be used to link to this page
Your browser does not support the video tag.