My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1997
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
TURNER
>
2420
>
2300 - Underground Storage Tank Program
>
PR0231382
>
COMPLIANCE INFO_1997
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/9/2020 8:56:06 PM
Creation date
6/3/2020 9:48:07 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1997
RECORD_ID
PR0231382
PE
2361
FACILITY_ID
FA0004139
FACILITY_NAME
Plaza liquor and Gas
STREET_NUMBER
2420
Direction
W
STREET_NAME
TURNER
STREET_TYPE
RD
City
LODI
Zip
95242
CURRENT_STATUS
01
SITE_LOCATION
2420 W TURNER RD
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231382_2420 W TURNER_1997.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
397
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> OMNIFLEX IIT"" COAXIAL PIPING SYSTEM <br /> BURIAL SPECIFICATIONS <br /> Minimum Minimum Sand or <br /> Pipe Size Surface Condition Burial Depth Pea Gravel Above Pipe, <br /> 1-1/2" Unpaved 17" 12" <br /> (Omniflex II-) Paved,Minimum 4"Asphalt 12" 8" <br /> Paved,;Minimum 4" Concrete 9" 6" <br /> Minimum burial depths shown in the above table are Multiple lines in the same ditch should be separated by a <br /> acceptable if,and only if,the following conditions are met: minimum of 4" if special precautions are taken to insure <br /> 1. The ditch width is 2-1/2' or less. that backfill material is placed under and around the pipe. <br /> 2. The paved surfaces extend at least 2' on either side of In all cases there must never be a void of backfilll under <br /> the ditch. or around the pipe. <br /> 3. The fill material is clean sand or 1/8"to 3/4"pea gravel. The maximum allowable burial is 23' for burial in <br /> 4. Six inches of fill material is placed under the pipe as moderately compacted soils which do not contain clay <br /> bedding material. and where the soil modulus is at least 1000 psi. <br /> Remaining backfill above the sand or pea gravel amounts If you have any further questions, please contact your <br /> shown in the last column can be native soil if desired. local TCI Representative. <br /> AS REQUIRED FOR LISTING WITH UNDERWRITERS' LABORATORIES OF CANADA,OMNIFLEX II'"'COAXIAL PIPING SYSTEMS MUST BE <br /> INSTALLED WHEN AMBIENT TEMPERATURE IS ABOVE OOF. <br /> 27' 27• 2 <br /> 1 <br /> ---moi <br /> a � <br /> Pe 25 18 <br /> lI MUST ALLOW MINIMUM 1/8"SLOPE PER FOOT <br /> PREPARING THE SITE <br /> Step One—Layout Step Two <br /> To excavate for pipe trench,determine design layout from Compute slope from furthest dispenser to tank(s). Allow <br /> one dispenser island to next. Keep 3' minimum bend minimum 1/8"slope per foot for Omniflex pipe.This slope <br /> radius on Omniflex pipe. determines depth of pipe trench and tank(s). <br /> A) For product labeling uni- Step Three <br /> formity, enter dispenser sump Bed pipe chase with minimum of 6"of approved bedding/ <br /> from same direction. backfill material (pea gravel, sand, or other prior TCI <br /> approved material). Bed of pipe chase must be raked to <br /> B) If order of product labeling even plane,incorporating minimum 1/8"per foot of slope <br /> can reverse with each succes- from furthest dispenser towards tank field. <br /> sive dispenser,less piping may <br /> be used. Step Four— Tank Sumps <br /> Before installation of piping, mount tank sumps to un- <br /> derground storage tanks (see Tank Sump Installation • <br /> Note: For Omniflex II"system,use uncuffed sumps ONLY. Instructions for additional information). <br /> Page 1 - Omniflex Instructions <br />
The URL can be used to link to this page
Your browser does not support the video tag.