My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2002-2006
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
3425
>
2300 - Underground Storage Tank Program
>
PR0231416
>
COMPLIANCE INFO_2002-2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/21/2024 3:43:58 PM
Creation date
6/3/2020 9:48:25 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2002-2006
RECORD_ID
PR0231416
PE
2361
FACILITY_ID
FA0003627
FACILITY_NAME
ARCO 02093
STREET_NUMBER
3425
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95376
APN
21418020
CURRENT_STATUS
01
SITE_LOCATION
3425 TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231416_3425 TRACY_2002-2006.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
344
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
D. Results of Testing/Servicing E T Dispatch <br /> Software Version Installed: <br /> Complete the foliowing checklist: <br /> a"Yes D No- Is the audible alarm operational? <br /> '"Yes ZI No* Is the visual alarm operational? <br /> 4.71 Yes 0 No* Were all sensors visually inspected.functionally,tested. and confirmed operational? <br /> Yes :1 No* Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will <br /> not interfere with their proper operation? <br /> Z1, Yes ZI No* If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modem) <br /> Z'N/A operational? <br /> E-1 Yes 2 No* For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment <br /> D N/A monitoring system detects a leak fails to operate, or is electrically disconnected? If Yes:which sensors initiate <br /> positive shut-down? (Check all that apply) 'dump/Trench Sensors; dispenser Containment Sensors. <br /> Did you confirm positive shut-down due to leaks and sensor failure/disconnection? 2-yes; El No. <br /> U Yes No* For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e. no <br /> 0 N/A mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank <br /> fill point(s)and operating properly? If so,at what percent of tank capacity does the alarm trigger? % <br /> U Yes* ZI No Was any monitoring equipment replaced? If yes,identify specific sensors,probes, or other equipment replaced <br /> and list the manufacturer name and model for all replacement parts in Section E,below. <br /> D Yes* RNo Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply)0 <br /> Product; 0 Water. If yes,describe causes in Section E,below. <br /> 2'Yes Zl No* Was monito cr system set-up reviewed to ensure proper s2jt�ms?Attach set up reports,if ap <br /> rin, 2livable <br /> a Yes D No" Is all monitoring 291ipmento perational per manufacturer's specifications? <br /> * In Section E below,describe how and when these deficiencies were or will be corrected. <br /> E. Comments: 12 3� r- :r—C <br /> e 0 ue ZO '2'Z M atlg2e Pe L.,i'skv&s- ' '�-2-2'1,5c <br /> Page 2 of 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.