Laserfiche WebLink
1 • • <br />Integrated solutions for centralized, <br />singe system vapor recovery <br />TLS Monitoring System Requirements <br />ISD is compatible with the TLS-350/EMC w/BIR, TLS -350 <br />Plus/EMC Enhanced, TLS-350/EMC consoles with the following <br />minimum requirements/features: <br />• ECPU2 and TLS console version 25C software (or greater) <br />• RS -232 Interface, for example: a RS -232 Interface Module, a <br />Dual -Port RS-232/RS-485 Interface Module, etc. <br />• Dispenser Interface Module (DIM) <br />• Submersible Turbine Pump (STP) shutdown control hardware, <br />for example: a Four -Relay Output Interface Module, a Three <br />Output Pressurized Line Leak Control Module (must be used in <br />conjunction with PLLD), etc <br />• TLS console must have and integral printer, probes and the <br />appropriate number of sensor interface modules <br />Alarm Table <br />The following table contains a list of warnings and alarms <br />generated by the ISD system. <br />Warning <br />Days to <br />Alarm <br />Description <br />ISD DEGRD PRESSURE <br />30 <br />Vapor Overpressure Problem <br />ISD GROSS PRESSURE <br />7 <br />Vapor Overpressure Problem <br />ISD VAPOR LEAKAGE <br />7 <br />Vapor Leakage Problem <br />ISD SENSOR OUT <br />7 <br />Sensor Problem <br />ISD SETUP <br />7 <br />Setup Problem <br />Hnn: DEGRD COLLECT <br />7 <br />Hose AIL Problem <br />Hnn: GROSS COLLECT <br />1 <br />Hose Blockage or A/L Problem <br />Hnn: FLOW COLLECT <br />1 <br />Hose Blockage Problem <br />ISD VP STATUS <br />I <br />Vapor Processor Problem <br />ISD VP PRESSURE <br />1 <br />Vapor Processor Problem <br />ISD System Requirements <br />The following table contains pricing, part numbers as well as a description for the <br />ISD components. <br />Part No. Description Monitored Item(s) <br />330020-445 Vapor Flow Meter (Sensor) Kitt 1 per dispenser <br />330020-515 Vapor Pressure Sensor Kitt' 1 per station <br />331943-203 NVMEM 2 (Report Storage) 1 per console <br />330160-xxx Software Enhancement Module (SEM) 1 per console <br />2The vapor flow meter and vapor pressure sensor are intrinsically safe sensors that connect to either the Eight Input <br />Smart Sensor Interface Module (P/N 329356-004) or the Seven Input Smart Sensor Module w/Embedded Pressure <br />Sensor Interface Module (P/N 332250-001.) <br />'The vapor pressure sensor hit includes ISD system manuals. <br />Typical installation <br />Diepenser hydreulim-caainel <br />The following figure b I ISD Pressure Sensor <br />shows a typical ISD i (lntdispenser only) � <br />/ <br />Cable <br />installation in the base of <br />--- <br />a dispenser. i --- <br />_ - <br />--� <br />--- <br />�"tET <br />Pressure sensing portspens <br />Vapor realm lierne <br />� <br />ISD Rm Meter <br />item di <br />I <br />(installed enylMere <br />n line.) <br />set valve) <br />shea� <br />Cable/(snpdied) <br />Junction box <br />customer <br />Ar— must <br />point down <br />1/4' OD <br />rigatubeg <br />required <br />I <br />_ <br />Pitch toVapor <br />seal on <br />(customer <br />I <br />amEr <br />drain 1/4' <br />realm line <br />supplied) <br />Flow mater wart ---- <br />�• <br />-- <br />shear valve <br />- -— - -_- -- <br />- ---- <br />hotlmn.1 <br />O <br />O <br />COMuit to <br />____.._ ______. ___.. <br />Top of pedestal island I <br />_ ___. _. <br />_ ______. ___ <br />_TLS Canede--I <br />Q <br />o- _--- - - - - - <br />- - <br />O- - - -- <br />00"O �� `� A test <br />- - - - <br />port is required for <br />rodtdng <br />�0()60�Q40UQ1 Tbackpreswre <br />liquidd lumg I <br />teal, <br />Flow Meter <br />ihe�same <br />anddPressure <br />share <br />mMui�consoole <br />Q <br />Ip� <br />C)IQ/, 0 opo <br />O� <br />I"00 <br />40 <br />2 or 7 common main vapor return line <br />1 <br />0 Q 1� <br />0 11 1 ao . Dispenser sump — <br />— — — — — — — — — — — — <br />— — — — <br />—I QC <br />For more information call <br />1-888-561-7942 <br />i © 2005 Veeder-Root Company • 125 Powder Forest Drive • Simsbury, CT 06070 • USA <br />VEEDER-ROOT <br />Telephone: 860-651-2700 • Fax: 860-651-2719 • www.veeder.com <br />VR 13753 P/N 0576047-065 RevB Printed in USA <br />