Laserfiche WebLink
E <br />ISWRCB, January 2002 <br />IE <br />Page _3_ of —9- <br />Final Reading (RF): <br />4. TANK ANNULAR TESTING <br />10" <br />10" <br />Test Method Developed By: <br />❑ Tank Manufacturer ® Industry Standard ❑ Professional <br />Engineer <br />1 HR <br />❑ Other (Spec) <br />1 HR <br />Change in Reading (RF -RI): <br />0" <br />Test Method Used: <br />❑ Pressure <br />® Vacuum <br />❑ Hydrostatic <br />NO LOSS <br />❑ Other (Specify) <br />NO LOSS <br />NO LOSS <br />Test Result: <br />Test Equipment Used: 0 — 30" VACUUM <br />GAUGES <br />Pass ❑ Fail <br />Equipment Resolution: + / - 0.002" <br />Pass ❑ <br />Fail <br />OEM <br />Was sensor removed for testing? <br />ElIKEEMENSim <br />®Yes [:]No ❑ NA <br />Tank # 87(1) <br />Tank # 87(2) <br />Tank # 87(3) <br />Tank # 91 <br />Is Tank Exempt From Testing?' <br />ElYes ® No <br />ElYes ® No <br />ElYes ® No <br />ElYes ® No <br />Tank Capacity: <br />10000 <br />10000 <br />10000 <br />10000 <br />Tank Material: <br />FIBERGLASS <br />FIBERGLASS <br />FIBERGLASS <br />FIBERGLASS <br />Tank Manufacturer: <br />XERXES <br />XERXES <br />XERXES <br />XERXES <br />Product Stored: <br />87 <br />87 <br />87 <br />91 <br />Wait time between applying <br />pressure/vacuum/water and <br />10 MIN <br />10 MIN <br />10 MIN <br />10 MIN <br />starting test: <br />Test Start Time: <br />9:00 AM <br />9:00 AM <br />9:00 AM <br />9:00 AM <br />Initial Reading (RI): <br />10" <br />10" <br />10" <br />10" <br />Test End Time: <br />10:00 AM <br />10:00 AM <br />10:00 AM <br />10:00 AM <br />Final Reading (RF): <br />10" <br />10" <br />10" <br />10" <br />Test Duration: <br />1 HR <br />1 HR <br />1 HR <br />1 HR <br />Change in Reading (RF -RI): <br />0" <br />0" <br />0" <br />0" <br />Pass/Fail Threshold or Criteria: <br />NO LOSS <br />NO LOSS <br />NO LOSS <br />NO LOSS <br />Test Result: <br />®;'Pass ❑ Fall <br />0 <br />Pass ❑ Fail <br />® <br />Pass ❑ <br />Fail <br />N'Pass ❑ Fall <br />Was sensor removed for testing? <br />® Yes [:]No ❑NA <br />®Yes [:]No ❑ NA <br />Oyes ❑ No ❑ NA <br />®Yes [:]No ❑ NA <br />Was sensor properly replaced and <br />verified functional after testing? <br />®Yes ❑ No[]No <br />[:INA <br />® yes ❑ NA <br />®Yes [:]No ❑ NA <br />®Yes [--]No ❑ NA <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />' Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary <br />containment, such as systems that are hydrostatically monitored or under constant vacuum, are exempt from periodic containment <br />testing. {California Code of Regulations, Title 23, Section 2637(a)(6)) <br />