Laserfiche WebLink
ANNUAL,ILL CONTAINER TESOREPORT <br />TEST DATE: June 7, 2011 <br />Al. FACILITY <br />A2. OWNER <br />Name <br />Quik Stop Market #124 <br />San Joaquin County Environmental Health <br />Name <br />Quik Stop Markets, Inc. <br />Address <br />505 N. Main Street, Manteca, CA 95336 <br />600 E. Main Street, Stockton, CA 95202 <br />Address <br />4567 Enterprise Street, Fremont, CA 94538 <br />Phone # <br />510-657-8500 <br />June 1, 2011 <br />Phone # <br />510-657-8500 <br />Contact <br />Michael Karvelot <br />None <br />Contact <br />Michael Karvelot <br />Dulcinea Covan <br />Phone # <br />209-468-8257 <br />A3. C U P A <br />A4. TESTING CONTRACTOR <br />Name <br />San Joaquin County Environmental Health <br />Name <br />Walton Engineering, Inc. <br />Address <br />600 E. Main Street, Stockton, CA 95202 <br />Address <br />P.O. Box 1025, W. Sacramento, CA 95691 <br />Notified <br />June 1, 2011 <br />Lic# <br />617238 A, B, Haz <br />Inspector <br />None <br />Contact <br />Dulcinea Covan <br />Phone # <br />209-468-8257 <br />Phone # <br />916-373-1166 <br />K. SPILL CONTAINER TEST RESULTS <br />measuring equipment used: ualdwell <br />Tank Number <br />Product contained <br />Spill container capacity (US gallons) <br />Spill container manufacturer <br />Spill container depth (inches) <br />Is the spill container located in a sump? <br />Does sump have a liquid sensor installed? <br />Condition of spill container prior to testing <br />Portion of spill container tested <br />Depth of water level from bottom (inches) <br />Wait time for water level to stabilize (hr:min) <br />Test start time <br />Test end time <br />Test duration (hr:min) <br />Change in water level (± 0.000 inches) <br />Pass/Fail threshold (0.005 inches /'/2 Hr.) <br />TEST RESULT <br />L. COMMENTS: <br />1 <br />Gasoline - 87 <br />5 <br />OPW <br />15.00 <br />Yes <br />No <br />Dry <br />Entire <br />13.50 <br />0:05 <br />9:12 <br />9:42 <br />0:30 <br />0.000 <br />0.005 <br />PASS <br />The MSC test water was left on site in owner supplied drum. <br />The drum is half full and dated 12/20/10. <br />Replaced the 89 fill cap for hydro test. <br />Signature: <br />Technician: 0 <br />I <br />zuui / walton tngineenni, <br />2 <br />Gasoline - 89 <br />5 <br />OPW <br />15.50 <br />Yes <br />No <br />Dry <br />Entire <br />13.00 <br />0:05 <br />9:48 <br />10:18 <br />0:30 <br />0.000 <br />0.005 <br />PASS <br />WALTON _.. <br />ENGINEERING, INC. <br />Unange In <br />3 <br />Gasoline - 91 <br />5 <br />OPW <br />15.00 <br />Yes <br />No <br />Dry <br />Entire <br />13.50 <br />0:05 <br />10:07 <br />10:37 <br />0:30 <br />0.000 <br />0.005 <br />PASS <br />Date: jure 7, 2011 <br />